Hoshizaki JWE-24000CUA-L-25B Functions, Sequence of Operation, Increasing Rinse Water Flow Rate

Page 14

B. Functions

1. Increasing Rinse Water Flow Rate

The rinse water flow rate is factory adjusted to 1.90 gal/min (7.2 L/min). To increase the flow rate to 3.17 gal/min (12 L/ min), follow the steps below. Hot water supply of at least 3.44 gal/min (13 L/min) and 113°F (45°C) will be required.

Upper Rinse Spray Arm

Clean Pipe

Lower Rinse

Nut

Spray Arm

 

1)

Remove the upper and lower rinse spray arms.

Spacer

2)

Loosen the clean pipe nut, and remove the clean pipe.

 

3)Remove the spacer (with 4.5 mm DIA hole) from the nut at the unit side.

4)Replace the clean pipe and the upper and lower rinse spray arms in their correct positions.

C. Sequence of Operation

The steps in the sequence are as outlined below.

1. Auto Fill Cycle

"AUTO FILL" lamp flashing and "RINSE TEMP." or "WASH TEMP." lamp on.

If BT WLF/S is open when the "ON/OFF" button is pressed, WV energizes after BT auto fill delay time (factory default: 10 seconds).

When BT WLF/S closes, WV de-energizes, the "AUTO FILL" lamp flashes and the auto fill cycle starts.

RPM energizes for length of time set by the auto fill cycle rinse time setting (factory default: 13 minutes). For details, see "Auto Fill Cycle Rinse Time" (service menu item 03) in "II.F.7.b) Service Menu Chart."

At the end of the auto fill cycle, there is a 5-second dwell time. CB checks WT WLS. If WT WLS is closed, BZ beeps, the "AUTO FILL" lamp goes off and the "READY" lamp comes on. If WT WLS is open, BZ beeps continuously, the "AUTO FILL" lamp goes off and "A1" flashes in the display. For details, see "III.B.3.a) Auto Fill Error (A1)."

If the BT water level goes down and BT WLF/S opens during the auto fill cycle, WV energizes after BT auto fill delay time (factory default: 10 seconds). For adjustment of this delay time, see "Booster Tank Auto Fill Delay Time" (service menu item 08) in "II.F.7.b) Service Menu Chart." If delay time is set shorter, WV energizes/de-energizes frequently and BT may not supply hot water of proper temperature.

If SP is opened during the auto fill cycle, SPS opens, RPM de-energizes. The "AUTO FILL" lamp keeps flashing and the rinse cycle time keeps counting down. When SPS closes again, RPM energizes.

If WLS is closed when the "ON/OFF" button is pressed, the "READY" lamp comes on and the unit is ready to start.

Note:

1.If SP is opened during the auto fill cycle, RPM de-energizes to stop hot water supply. If SP is left open for a long time, WT may not fill by the end of the auto fill cycle. In this case, WT WLS opens when the unit starts, and the supplementary fill cycle begins.

2.WTH is energized when WT WLS closes during the auto fill cycle.

3.BTH is energized during the auto fill cycle if WLSF/S is closed.

9

Image 14
Contents Model JWE-2400CUA-L-25B JWE-2400CUA-R-25B Hoshizaki AMERICA, INC Contents Page Property Important Safety InformationSerious injury Indicates important information about the use and careDishwasher Side Booster Side AC Supply Voltage Right to Left Nameplate Rating Dimensions/Connections JWE-2400CUA-L-25BJWE-2400CUA-R-25B II. General Information A. Construction DishwasherBooster Tank Top ViewBox Increasing Rinse Water Flow Rate FunctionsSequence of Operation Page Drain Table Limit SwitchEmergency Stop Button Flow Chart Dishwasher Sequence Flow Chart JWE-2400CUA-25BCycle ChartAuto Fill Wash Cycle/Rinse Cycle Control Board and Operation Board Control Board LocationControl Board Layout CN4Control Board Diagram CN1 CN2Water Temperature Lamps Service Menu and Error LogError Codes DisplayReady Lamp Conveyor Speed SwitchService Menu Access Wash LampService Menu Chart Item and Details Setting Range DisplayBuzzer Temperature DisplayError Codes Operation Time Display Continuous Wash ModeLow Water Temperature Lock Function Special ModesOFF Switch Open/Closed Display Mode III. Service DiagnosisDiagnostic Procedure Page Error Codes Error Code TableError Code Log Error Code Details Auto Fill Error A1Page Booster Tank Auto Fill Error A2 Wash Tank Water Level Error A3 Page Page Wash Tank Thermistor Error H1, H2 Booster Tank Thermistor Error H3, H4 ROM/RAM Error H5 Eeprom Error H6Conveyor Overload or Table Limit Error 1 L1 Conveyor Overload or Table Limit Error 2 L2 Booster Tank Error b1 Booster Tank Water Level Safety Error b2 Service Flow Charts Unit Will Not StartSee III.B. Error Codes Replace Dishes Not Clean Page Inadequate Rinse Dishwasher Will Not Start Wash/Rinse Cycle Dishwasher will not start wash/rinse cycleNo or Inadequate Detergent/Rinse Aid Supply Wash Tank Water BoilsWash Tank Water Not Draining Float Switch Cleaning Float Switch Check and CleaningFloat Switch Check Thermistor Check Removal of Panels IV. Removal and Replacement of ComponentsRemoval and Replacement of Wash Pump Motors Removal and Replacement of Rinse Pump Motor Rinse Pump Motor Page Removal and Replacement of Gear Motor Removal and Replacement of Conveyor Removal and Replacement of Crankshaft Removal and Replacement of Control Box Removal and Replacement of ThermistorRemoval and Replacement of Control Board or Operation Board Control BoardOperation Board Removal and Replacement of Heater Removal and Replacement of Float Switch Removal and Replacement of Thermostat Cleaning and Maintenance Instructions Daily Maintenance Wash the curtains Silverware Rack Rail Ring Install the curtain L in the wash compartment Heater Weekly MaintenanceMonthly Inspection ExteriorDescaling As Required ShutdownService Panel Hook Long Storage, Relocation, Disposal, Transfer VI. Operating InstructionsVII. Technical Information Water Circuit Wiring Diagram
Related manuals
Manual 61 pages 38.47 Kb

JWE-2400CUA-R-25B, JWE-24000CUA-L-25B specifications

The Hoshizaki JWE-2400CUA-R-25B and JWE-24000CUA-L-25B are advanced ice machines designed to meet the diverse needs of commercial establishments requiring high volumes of ice. These state-of-the-art units combine innovative technology with energy efficiency, making them ideal for restaurants, hotels, bars, and other hospitality settings.

One of the main features of the JWE-2400CUA-R-25B is its high production capacity. This model can produce up to 2,400 pounds of ice in a 24-hour period, ensuring a continuous supply for busy operations. Similarly, the JWE-24000CUA-L-25B boasts an impressive production rate, accommodating even larger establishments. Both machines deliver crescent-shaped ice, which is favored for its rapid cooling properties and ease of use in beverages.

Energy efficiency is a highlight of both models. They are designed with environmentally friendly refrigerants, aligning with modern sustainability practices. These machines also incorporate advanced heat-exchange systems that maximize energy savings while maintaining optimal ice production. As a result, operators can enjoy significant reductions in energy costs without compromising on performance.

Durability and reliability are essential characteristics of the Hoshizaki JWE series. Constructed with high-quality materials, these units feature stainless steel exteriors that resist corrosion and wear, ensuring long-term operation in demanding environments. Additionally, the ice-making components are built to endure frequent use, allowing for consistent ice output over time.

The technology integrated into the JWE-2400CUA-R-25B and JWE-24000CUA-L-25B includes user-friendly digital controls that simplify operation and monitoring. These controls help operators track production levels, ice thickness, and machine status, allowing for proactive maintenance and reducing downtime. Furthermore, routine cleaning and maintenance are made straightforward, contributing to enhanced hygiene and overall ice quality.

In conclusion, the Hoshizaki JWE-2400CUA-R-25B and JWE-24000CUA-L-25B ice machines present a perfect blend of high capacity, energy efficiency, and durability. Their advanced features and technologies make them a reliable choice for any business requiring dependable ice production. With their user-friendly controls and robust design, these machines stand out as top contenders in the commercial ice maker market.