Hoshizaki KMS-1401MLJ, Condensing Unit Models SRK-14J/3 Performance Data, Production PER 24 HR

Page 28

C. Performance Data

1. KMS-1401MLJ with SRK-14J

APPROXIMATE ICE

AMBIENT TEMP.

 

 

 

WATER TEMP. (ºF/ºC)

 

 

PRODUCTION PER 24 HR.

(ºF/ºC)

 

50/10

 

70/21

 

 

90/32

 

 

 

 

70/21

 

1420

644

1379

626

1278

580

 

 

 

 

80/27

 

1389

630

1325

601

1199

544

lbs./day

 

kg./day

90/32

 

1379

626

1280

581

1162

527

 

100/38

 

1344

609

1252

568

1054

478

 

 

 

 

 

 

 

 

 

 

 

APPROXIMATE ELECTRIC

70/21

 

2410

 

2439

 

 

2492

CONSUMPTION

80/27

 

2432

 

2478

 

 

2537

 

 

 

 

90/32

 

2439

 

2510

 

 

2567

watts

 

 

 

100/38

 

2454

 

2523

 

 

2620

APPROXIMATE WATER

70/21

 

682

2.58

555

2.10

492

1.86

CONSUMPTION PER 24 HR.

80/27

 

585

2.22

388

1.47

386

1.46

 

 

m3/day

90/32

 

555

2.10

250

0.94

220

0.83

gal./day

 

100/38

 

411

1.56

243

0.92

193

0.73

FREEZING CYCLE TIME

70/21

 

24

 

25

 

 

27

 

 

 

 

80/27

 

25

 

26

 

 

29

 

 

 

 

90/32

 

25

 

27

 

 

30

min.

 

 

 

100/38

 

26

 

28

 

 

33

HARVEST CYCLE TIME

70/21

 

4.6

 

3.9

 

 

3.6

 

 

 

 

80/27

 

4.0

 

3.0

 

 

3.1

 

 

 

 

90/32

 

3.9

 

2.2

 

 

2.2

min.

 

 

 

100/38

 

3.1

 

2.2

 

 

2.1

HEAD PRESSURE

70/21

 

178

12.5

197

13.8

219

15.4

 

 

 

 

80/27

 

192

13.5

221

15.6

241

17.0

 

 

 

 

90/32

 

197

13.8

242

17.0

263

18.5

PSIG

kg/cm2G

100/38

 

200

14.1

247

17.4

283

19.9

SUCTION PRESSURE

70/21

 

46

3.2

47

3.3

50

3.5

 

 

 

 

80/27

 

47

3.3

49

3.5

52

3.7

 

 

 

 

90/32

 

47

3.3

51

3.6

54

3.8

PSIG

kg/cm2G

100/38

 

48

3.4

52

3.6

56

3.9

TOTAL HEAT OF REJECTION FROM CONDENSER

 

28,800 BTU/h [AT 90ºF (32ºC) / WT 70ºF (21ºC)]

CONDENSER VOLUME

 

 

 

226 CU. IN (SRK-14J)

 

 

 

Note:

1.Pressure data is recorded at 5 minutes into freezing cycle. The data not in bold should be used for reference only.

2.We reserve the right to make changes in specifications and design without prior notice.

28

Image 28
Contents Modular Crescent Cuber Serenity Series Model Hoshizaki AMERICA, INC Contents Page Important Safety Information For KMS For SRKSpecifications Icemaker KMS-1401MLJ with SRK-14JData Pending KMS-1401MLJ with SRK-14J3Condensing Unit SRK-14JSRK-14J3 II. General Information Construction IcemakerCondensing Unit Sequence of Operation Sequence Cycles and ShutdownMinute Fill Cycle Initial Harvest CycleS4 Dip Switch Setting Pump-Out 1st Pump-Out Frequency Pump-Out CycleHarvest Cycle ShutdownFlow SequenceControl Board Control Board Layout Control BoardLED Lights and Audible Alarm Safeties No. of Beeps Type of Alarm Every 3 secSequence Step Energized Time LEDs are On Components Min Max AvgControls and Adjustments Default Dip Switch SettingsS4 Dip Switch Harvest Timer S4 dip switch 1Pump-Out Frequency Control S4 dip switch 5 Pump-Out Timer S4 dip switch 3S4 Dip Switch Setting Time seconds Inlet Water Valve Harvest Pump Timer S4 dip switch Factory Use S4 dip switchFreeze Timer S4 dip switch 9 S4 Dip Switch Setting Pump Motor Time secondsFloat Switch Selector S5 dip switch Refill Counter S5 dip switch 2 throughS5 Dip Switch Setting No. of Refills No.4 RefillControl and Service Switches DrainCirc WashIII Transformer 10.5V at Wiring DiagramsControl Output Control Transformer Output 10.5V atWire Harness Connections Wire Harness ConnectionsSRK Condensing Unit KMS Icemaker Unit factory connectedPerformance Data Production PER 24 HRData Pending IV. Service Diagnosis Diagnostic ProcedurePage Page Page Control Board Check Bin Control Check and Cleaning Bin Control CheckBin Control Cleaning Float Switch Check and Cleaning Float Switch CheckFloat Switch Cleaning Thermistor Check No Ice Production Diagnostic ChartsNo Ice Production Possible Cause Freeze-Up Freeze-Up Possible Cause Harvest CycleFreeze-Up Possible Cause Freeze CycleLow Ice Production Possible Cause Long Harvest Cycle Low Ice ProductionLong Freeze Cycle Service for Refrigerant Lines Replacement of ComponentsRefrigerant Recovery Brazing Evacuation and Recharge R-404APage Important Notes for Component Replacement ComponentVI. Cleaning and Maintenance Cleaning and Sanitizing InstructionsCleaning Procedure Sanitizing Procedure Following Cleaning Procedure Maintenance Stainless Steel ExteriorStorage Bin Scoop Dispenser Unit/Storage BinPreparing the Icemaker for Periods of Non-Use Page VII. Disposal

Condensing Unit Models SRK-14J/3, KMS-1401MLJ specifications

The Hoshizaki KMS-1401MLJ and the Condensing Unit Models SRK-14J/3 are critical components in the commercial refrigeration sector, designed to provide efficient and reliable cooling for various applications. These models stand out for their exceptional performance, advanced technologies, and robust characteristics that meet the demanding needs of food service, hospitality, and retail establishments.

One of the primary features of the Hoshizaki KMS-1401MLJ is its high-capacity cooling capability. With a refrigerating capacity suitable for larger applications, this unit is designed to handle significant load demands while maintaining energy efficiency. This is particularly advantageous in environments where consistent temperature control is vital for preserving perishable goods.

The SRK-14J/3 models further enhance the functionality of this system by incorporating advanced inverter technology. This innovation allows for variable speed operation, adjusting the compressor's output based on the actual cooling demand. As a result, users can experience reduced energy costs and lower environmental impact. This efficiency not only decreases the overall operating expenses but also extends the lifespan of the unit due to reduced wear and tear on the compressor.

The Hoshizaki units are also renowned for their user-friendly interface, which features intuitive controls for easy operation and monitoring. This ensures that users can quickly adjust settings to accommodate specific storage needs, improving overall convenience and efficiency in the workplace.

Additionally, both the KMS-1401MLJ and the SRK-14J/3 models are designed with durability in mind. Constructed from high-quality materials, they are built to withstand the rigorous demands of a commercial kitchen or storage facility. Features such as corrosion-resistant coatings and robust insulation enhance the longevity of these units, making them a wise investment for business owners.

In terms of maintenance, Hoshizaki has incorporated several design elements to facilitate ease of service. Access points for routine checks and cleaning have been strategically placed, enabling technicians to perform maintenance tasks without disrupting the operation of the units.

In conclusion, the Hoshizaki KMS-1401MLJ and Condensing Unit Models SRK-14J/3 offer a perfect blend of efficiency, durability, and technological advancement. Their ability to provide reliable cooling solutions makes them integral to any establishment focused on quality and performance in food and beverage storage. For businesses seeking to enhance operational efficiency while ensuring the preservation of their products, these models represent a leading choice in the commercial refrigeration market.