Table 51. Symptom-to-FRU index (continued)

Problem

 

 

 

indicator

Component

Possible cause

Possible solutions

 

 

 

 

Hard disk drive

Several CRUs

Drive or drives

Replace failed drive or drives.

not visible in RAID

 

failed

 

management

 

 

 

 

FC cable failed

Replace FC cable.

software

 

 

 

 

 

SFP failed

Replace SFP.

 

 

 

 

 

 

 

 

RAID controller

Replace RAID controller.

 

 

failure

 

 

 

 

 

 

 

Midplane failure

Have the midplane replaced.

 

 

 

Contact an IBM technical support

 

 

 

representative.

 

 

 

 

 

 

Drive CRU has

Replace the drive CRU.

 

 

interface problem

 

 

 

with the ESM or

 

 

 

controller.

 

 

 

 

 

 

 

Incorrect firmware

Verify that the DS4700 Express

 

 

version

Storage Subsystem has the

 

 

 

correct firmware version. Refer to

 

 

 

“Software and hardware

 

 

 

compatibility and upgrades” on

 

 

 

page 20.

 

 

 

 

 

 

A controller has

Replace the failed controller and

 

 

failed in addition to

ESM.

 

 

the ESM failure in

 

 

 

the drive channel

 

 

 

that originates from

 

 

 

the functioning

 

 

 

controller.

 

 

 

 

 

Parts listing

Figure 120 on page 189 and the following table provide a parts listing for the

DS4700 Express.

188IBM System Storage DS4700 Express Storage Subsystem: Installation, User’s and Maintenance Guide

Page 220
Image 220
IBM DS4700 manual Parts listing