Attention: All devices on the loop must have the same data transfer rate, which means that you must set the link rate on the storage expansion enclosure to the same rate as the storage subsystem to which it is connected. Information about supported DS4000 storage subsystems can be obtained from the certified Compatibility Matrix, which can be found at the following Internet location:

www-1.ibm.com/servers/storage/disk/ds4000/interop-matrix.html

Table 50. Data transfer rates for drive modules

Link Rate

 

 

 

Switch

Storage Subsystem

Storage Subsystem with

Storage Subsystem with

Setting

with 2 GB Drives

4 GB Drives

Mixed Drives

 

 

 

 

2 Gbps

Drives function in 2

Drives work in 2 Gbps

All drives work in 2 Gbps

 

Gbps mode.

mode.

mode.

 

 

 

 

4 Gbps

Drives do not come

Drives work in 4 Gbps

2 GB drives do not come

 

online.

mode.

online.

 

 

 

4 GB drives work in 4 Gbps

 

 

 

mode.

 

 

 

 

Use the following procedure to check the current setting of the data transfer rate and change it, if necessary:

1.Complete the power-off sequence described in “Turning off the storage subsystem” on page 134 ensuring that the DS4000 storage subsystem is turned off before any attached storage expansion enclosures.

2.Locate the Link Rate indicator LEDs. Figure 112 on page 163 shows the location of the Link Rate indicator lights on the back of the storage subsystem.

162IBM System Storage DS4700 Express Storage Subsystem: Installation, User’s and Maintenance Guide

Page 194
Image 194
IBM DS4700 manual Data transfer rates for drive modules