In addition, to download the latest version of the DS4000 Storage Manager host software, the DS4700 Express Storage Subsystem controller firmware and NVSRAM, and the latest DS4000 ESM firmware, go to the following Web site:
www.ibm.com/systems/support/storage/disk
The DS4000 Storage Manager client provides the best way to diagnose and repair
vDetermine the nature of the failure
vLocate the failed component
vDetermine the recovery procedures to repair the failure
Although the storage subsystem has Needs Attention LEDs, these LEDs do not necessarily indicate which component has failed or needs to be replaced, or which type of recovery procedure you must perform. In some cases (such as in the case of a hard disk drive exceeding its PFAs), the Needs Attention LED does not turn on. Only the DS4000 Storage Manager client can detect the failure.
For example, the recovery procedure for a Predictive Failure Analysis (PFA) flag (impending drive failure) on a drive varies depending on the drive status (hot spare, unassigned, RAID level, current logical drive status, and so on). Depending on the circumstances, a PFA flag on a drive can indicate a high risk of data loss (if the drive is in a RAID 0 volume) or a minimal risk (if the drive is unassigned). Only the DS4000 Storage Manager client can identify the risk level and provide the necessary recovery procedures.
Note: For PFA flags, the
Recovering from a
Attention: Not following the
Finding controller, storage expansion enclosure, and drive information
You can view a Storage Subsystem Profile to find controller, enclosure, and drive information for the storage subsystem and attached storage expansion enclosures. To view a Storage System Profile, perform the following steps:
1.Open the Storage Subsystem Management window from the DS4000 Storage Manager Enterprise Management window.
2.Select Storage Subsystem → View → Profile. A Storage Subsystem Profile window opens.
3.Select the Controllers tab.
4.Scroll through the list to find Board ID, Submodel ID, Product ID, and Product revision for the storage subsystem.
5.Select the Enclosures tab.
6.Scroll through the list to find the Product ID for supported storage expansion enclosures.