Remote Refrigeration System

Remote Condenser

Remote Refrigeration System

The Remote Refrigeration System is shown in the above diagram. During the freezing cycle, high temperature and high pressure liquid refrigerant is directed from the condenser through a mixing valve, receiver, liquid line solenoid heat exchanger and a filter drier. The expansion valve meters refrigerant to the coils on the back of the evaporator.

In low ambient conditions (below 70°F air temperature at the condenser) the mixing valve opens to mix discharge gas with liquid returning from the condenser, in the receiver, to maintain discharge and liquid line pressures.

The low temperature and pressure refrigerant leaving the evaporator is directed through the suction line heat exchanger and is returned to the compressor. There it is compressed to a high temperature and high pressure gas. It is then directed to a condenser to be converted again to a high pressure and high pressure liquid.

During the harvest cycle, the hot gas solenoid valve (normally closed during the freeze cycle), opens and directs the high temperature gas leaving the compressor into the evaporator. Once the evaporator has reached approximately 40°F, the harvest motor overcomes the capillary attraction of the ice and the evaporator releases the ice. At the end of the harvest cycle, the hot gas solenoid valve closes and another freeze cycle begins.

During the off cycle, the liquid line solenoid valve closes and the system will pump down to 10-20 psi to prevent refrigerant migration to the low side of the system.

Page 4

Image 10
Contents Ice-O-Matic INSTALLATION AND PARTS MANUAL REMOTE CONDENSERSMODELS VRC 11100 East 45th AvePage Remote Condenser IntroductionTable of Contents Visible Loss or Damage Freight Claim ProcedureFreight Claims Important Inspect Promptly Concealed Loss or DamageIce-O-Matic Parts and Labor WarrantyDomestic & International Limited Warranty GOVERNING LAWGeneral Information General Description IntroductionCondenser Location General Information Remote Refrigeration System Receiver Component DescriptionCondenser Fan Motor INSTALLATION NOTICE InstallationWITH COMPATIBLE ICE-O-MATICICE MAKERS Support Leg Installation-VRC Vertical Air Flow Page Proper Tubing Routing Description Service PartsRemote Condenser VRC1001Service Parts Remote Condenser