Installation Preparation
Professional Gas Cooktops
Tools &
Materials
Required:
•Saw
•Measuring tape
•Carpenter’s square
•Pipe and fittings as required.
•Manual gas line
•Gas pressure regulator (supplied)
•Large
•Pipe wrench
•
•5 foot, 5/8"
Note: Purchase new flexible line. DO NOT USE OLD, PREVIOUSLY USED FLEXIBLE LINE.
Power
Supply
Locations
Gas Supply: | 7" for 36" Models | |
• The natural gas models are designed to | 17" for 48" Models | |
operate at 6" to 14" water column pressure. | 2" | |
• The liquid propane models are designed to | Gas Line | |
operate at 11" to 14" water column pressure. | ||
to Cooktop | ||
A regulator is required at the L.P. source to | ||
| ||
provide a maximum of 14" water pressure to |
| |
the range regulator. |
|
•These gas cooktops are supplied with 1/2" NPT female gas connection located at the left rear corner.
• A minimum 5/8" dia. metal flexible line is | 16" | ||
required. |
|
|
|
|
|
| |
(Length must comply with local codes.) |
|
|
|
• For rigid connection, locate the pipe stub | Locate Gas Supply 2" Maximum |
|
|
| |||
within area shown. | Protrusion From Wall or on Floor 2" From Wall |
•Install a manual
Electric Supply: | • Locate the electric supply within the area | |
These cooktops must be supplied with 120 | shown or within reach of the cooktop’s six | |
volt, 60 Hz., and connected to a individual, | foot power cord. | |
properly grounded branch circuit protected | • To avoid tangling cord with items stored in | |
by a 15 amp circuit breaker or time delay fuse. | ||
the cabinet, locate the receptacle on rear | ||
| ||
The power cord of this appliance is equipped | wall, inside the cabinet. | |
with a | Receptacle Box Cover Plate | |
mates with a standard | ||
wall receptacle to minimize the possibility of |
| |
shock hazard from this appliance. | Three Prong Plug | |
If the electrical service provided does not |
| |
meet the above specifications, it is recom- |
| |
mended that a licensed electrician install an |
| |
approved outlet. |
| |
DO NOT UNDER ANY CIRCUMSTANCES, |
| |
CUT OR REMOVE THE THIRD (GROUND) |
| |
PRONG FROM THE POWER CORD. |
| |
DO NOT USE AN EXTENSION CORD WITH | Three Prong Receptacle | |
THIS APPLIANCE. |
|
6