Gilson 600MP manual Safety Precautions, Drum While the Mixer is Running

Page 4

1 – SAFETY PRECAUTIONS

THE FOLLOWING PRECAUTIONS ARE SUGGESTED TO HELP PREVENT ACCIDENTS. A CAREFUL OPERATOR IS THE BEST OPERATOR. MOST ACCIDENTS CAN BE AVOIDED BY OBSERVING CERTAIN PRECAUTIONS. READ AND PRACTICE THE FOLLOWING PRECAUTIONS BEFORE OPERATING THIS EQUIPMENT TO HELP PREVENT ACCIDENTS. EQUIPMENT SHOULD BE OPERATED ONLY BY THOSE WHO ARE RESPONSIBLE AND HAVE BEEN PROPERLY INSTRUCTED.

￿Read all operating and maintenance instruction before operating or servicing the mixer. Test run the empty unit prior to actual use.

￿A mixer is only as safe as its operator. Give complete and undivided attention to the operations of the mixer.

￿Know how to stop the mixer and engine/motor instantly in emergency situations.

￿Always keep all guard and safety devices and labels attached and in place before operating mixer. Close engine housing during mixer operation.

￿Keep inexperienced and unauthorized people away from the mixer at all times.

￿Never leave the mixer unattended when it is running

￿Shut off engine or disconnect electric power before making repairs or adjustments. NEVER REACH INTO DRUM OR PLACE TOOLS INTO

THE DRUM WHILE THE MIXER IS RUNNING.

￿Do not overfill- -do not attempt to exceed the mixer’s rated capacity.

￿Do not refuel the engine when it is hot or running.

￿Do not smoke while refueling the engine.

￿Block mixer wheels when in operation.

￿Keep the mixer well maintained and in good operating condition. Check periodically for loose or missing hardware.

￿Avoid loose clothing that could get caught in moving parts or on control levers.

KEEP HANDS AND FEET AWAY FROM MOVING PARTS.

3

Image 4
Contents Gilsjn Mixers Gilsjn MixersIntroduction Table of Contents Safety Precautions Drum While the Mixer is RunningAssembly and PRO-OPERATIONAL Checks Controls and Operations Clutch Control LeverTOW Pole Assembly Saftey ChainsOperating the Mixer Mixer TransportExtension Cords for Electric Motors Loading the Mixer CleaningDischarging the Mixer Trouble Shooting Guide for MP Mixers Drum Seal Housings Operating GuidelinesLubrication Masonry Construction GuidelinesMixing Shaft Bearings Drum Shaft Bearing HangersENGINE/MOTOR Wheel BearingsRubber Wiper Blades AdjustmentENGINE/MOTOR Drive Storage Page Drum & Drive Page Mixing Blades Page Engine Housing and Axle Page FRAME, Drive and Clutch Control Page Engine and Power Options Page Engine and Power Options Gilson Mixer Warranty HOW to Obtain Parts Service Information

600MP specifications

The Gilson 600MP series is a sophisticated line of multi-position magnetic stirrers that have gained a reputation for their exceptional performance and versatility in laboratories around the world. Designed to provide precise and reliable mixing, the Gilson 600MP excels in applications ranging from chemistry to biology and pharmaceutical research.

One of the main features of the Gilson 600MP is its ability to support multiple vessels simultaneously, making it an ideal choice for high-throughput environments. The device can handle up to six beakers or flasks concurrently, each equipped with its own magnetic stirring bar. This capacity allows researchers to conduct multiple experiments at once, significantly increasing efficiency and productivity in the lab.

The Gilson 600MP boasts advanced technology such as its embedded microprocessor, which regulates and controls various parameters such as speed and heating. This results in consistent stirring speeds and temperature control, crucial for sensitive applications where uniform results are required. The stirring speed is adjustable, allowing users to choose the optimal rate for their specific samples, ranging from gentle mixing to vigorous agitation.

Another remarkable aspect of the Gilson 600MP is its compact and ergonomic design. With a sleek footprint, the unit conserves valuable bench space while still providing ample mixing capacity. The user-friendly interface includes an easy-to-read digital display that shows real-time information, enabling quick adjustments as needed.

Furthermore, the Gilson 600MP is equipped with robust safety features, including over-temperature protection and an automatic shut-off mechanism, which safeguard both the equipment and the user during operation. Additionally, the device’s durable construction is designed to withstand the rigors of daily laboratory use, ensuring longevity and dependability.

In terms of versatility, the Gilson 600MP is compatible with a wide range of vessel sizes and materials, accommodating various experimental setups. Its ability to integrate with external temperature control devices further enhances its functionality, allowing for precise thermal management during reactions.

In conclusion, the Gilson 600MP is a remarkable tool in the laboratory, favored for its multi-position capabilities, cutting-edge technology, user-friendly design, and robust safety features. As more laboratories seek efficient solutions to enhance their workflow, the 600MP continues to be a go-to choice for researchers looking to achieve optimal mixing results.