Replacing Halogen Bulbs

The halogen bulbs used in the ceiling lighting of the wine vault will provide years of service under normal operating conditions. However, should a bulb burn out, refer to the following instructions to replace the bulb.

WARNING!

Halogen bulbs generate intense heat. Be certain power is off and lamps have sufficient time to cool before attempting to replace.

Bulbs may break during replacement. Be careful when removing or installing bulbs.

To replace a halogen bulb:

Step 1 Set the motion sensor switch to OFF. To ensure sufficient illumination, it may be necessary to use an auxiliary light while replacing the bulb.

Step 2 Twist the light shield counterclockwise to disengage the locking tabs, then pull straight down to remove.

Step 3 Remove the burned out bulb by pulling it straight out and replace the bulb with a 12 VAC, G4 Base, Bi-Pin 10-watt maximum halogen bulb.

Step 4 To reinstall the light shield, align the three tabs on the light shield with the slots in the light fixture. Twist the shield clockwise until the tabs lock in place.

Step 5 Set the motion sensor switch to AUTO.

To order replacement bulbs, call the Monogram Wine Vault Line at: 877.234.WINE (877.234.9463). The light bulb part number is WR02X12174.

Remove the light shield to

access the bulb.

Pull the bulb straight out

from the socket.

Use a 12 VAC, G4 Base, Bi-Pin, 10-watt max. halogen bulb. Light bulb part number is WR02X12174.

To order replacement bulbs,

call the Monogram Wine Vault Line at 877.234.WINE (877.234.9463).

27

Image 27
Contents Monogram Wine Vault Table of Contents Well done Important Safety Information Do not USE a Plug Designed for a 15-AMP or 20-AMP Circuit HOW to Connect ElectricityQuick Tour of Your Wine Vault Exterior FeaturesInterior Features Storage Racking System model ZWVS1000SR Interior Features Tasting Racking System model ZWVT1000SRCellar Management System Key Parts and Controls Back Up Your Wine Data My Cellar ViewTurning Off Your Machine Tips for Stocking Your Cellar the First TimePlan Ahead Before Stocking or Inventorying Your Cellar Temperature Setting Cooling SystemDrain Line Connection Condensate Evaporator Switch Power SwitchOperating the Cooling System Additional Cooling System Features To use the liquid thermostat Liquid Temperature DisplayVault Room Temperature Display Interior Door Release Lockable Entry DoorStorage model ZWVS1000SR Tasting model ZWVT1000SR Redwood Wine RacksTasting Racks model ZWVT1000SR Diamond BinsTaster’s Alcove To remove the storage drawerTo replace the storage drawer Ceiling Lighting Interior Lighting SystemTo Replace a Strand Environment Care and CleaningRecommended Cleaning Intervals for Key Components Cleaning the Exterior of the Wine VaultCleaning the Interior of the Wine Vault Cleaning the Interior WallsMaintaining the Redwood Racks Cleaning the Liquid Probe Cleaning the Door GasketCleaning the Drain Port Replacing Halogen Bulbs Rope Lighting TroubleshootingNormal Sounds You May Hear Ceiling lights do not come onEntry Door Redwood RacksWine Vault is too warm Cooling SystemCooling Unit does not operate Wine Vault is too coldMoisture forms on the outside of the cooling unit Compressor motor operates for long periodsFor Customers With Special Needs… Consumer ServicesIn-Home Repair Service Monogram Wine Vault LineWhat is Covered For Products Warranty InformationWhat Is and Is Not Covered for Software What Is Not Covered for ProductsImportant Notice For Both Product and Software Warranties Wine Terms APPENDIX-VINOLOGYCapacity Name Description Bottle SizesRight Glass for the Right Wine 20/20 Rule of Thumb for Serving TemperaturesAPPENDIX-THE Perfect Serve Choosing the Perfect GlassRich, Full-Bodied Reds Ideal Serving TemperaturesGE Consumer & Industrial