Emerson Process Management 3500 Transmitter Connecting input and output wiring

Page 8

STEP 4. Connecting input and output wiring

Connect input and output wiring to the appropriate terminals on the input/output wiring connector, which is the far right connector. Refer to Table 1 and to the card that is inserted into the sleeve on the top panel (shown in Figure 4).

Use 24 to 16 AWG (0,25 to 1,5 mm2) twisted-pair shielded wire.

Ground the shields at a single point only.

Table 1. Input/output wiring terminals

Terminal number

Designation

c 2+

a 2 –

 

 

c 4 +

a 4 –

 

 

c 6 +

a 6 –

 

 

c 8 +

a 8 –

 

 

c 10 +

a 10 –

 

 

c 12 +

a 12 –

 

 

 

 

c 14

+

a 14

 

 

 

 

c 16

+

a 16

 

 

 

 

c 18

+

a 18

 

 

 

 

c 32

(B line)

a 32

(A line)

Primary 4–20 mA output

Secondary 4–20 mA output

Frequency input

Discrete input 1

Discrete input 2

Frequency output

Discrete output 1

Discrete output 2

Discrete output 3

RS-485 output

Figure 4. Input/output wiring terminal card

STEP 5. Connecting the Model 3500 to the sensor

To connect the Model 3500 transmitter to a Micro Motion sensor, follow the steps below. If you are installing the Model 3300 applications peripheral, this step is not required.

7

Image 8
Contents Model 3500 Transmitter 9-wire or Model 3300 Peripheral Before YOU Begin European installations Installation kitChoosing a location Environmental requirementsDimensions Space requirements for proper ventilationDimensions for mounting in rack Flowmeter cable lengthsInstalling guide rails and wiring connectors Guide rails Wiring connectorsPositions of guide rails and wiring connectors Installing the Model 3300/3500 in the rackConnecting input and output wiring Input/output wiring terminalsIdentify the components shown in Figure Connecting power supply wiring Power supply wiring terminals 3300995