Tamron MST2000 Programming, Se lect the Pa ram e ter to Edit, Editing a Numeric Value Parameter

Page 11

PROGRAMMING

OPERATION MANUAL

7. PROGRAMMING

The MST2000 PROGRAM mode is accessed by pressing the MODE key. When the MODE key is pressed one of the fol low ing will oc cur.

þNOTE:

&The MST2000 can be Pass word pro tected to pre vent un au tho rized ac cess to pro gram ming pa rameters. The MST2000 is shipped from the fac tory with the Pass word dis abled.

7.1If the Pass word Pa ram e ter is En abled (else go to Sec tion 7.2)

A.The MST2000 will then dis play ENT_PW prompting the user to enter the re quired pass word.

þNOTE:

&The user must press the EDIT key within 4 sec onds to be gin en ter ing the cur rent pass word or the MST2000 will re- turn to RUN mode. The pass word is a unique num ber be tween 1 and 9999 and is en tered as de scribed in Sec tion 7.5.

&Dur ing pass word en try, if no keys are pressed for more than 4 sec onds, the MST2000 will re turn to RUN mode.

7.2 If the Pass word Pa ram e ter is Dis abled or af ter the Pass word is suc cess fully en tered.

After the pass word has been prop erly en tered, Brandt and verXXX will be mo men tarily dis played and then fol lowed by the first avail able PROGRAM pa ram e ter.

þNOTE: verXXX indicates the installed software revisionlevel.

7.3Se lect the Pa ram e ter to Edit

A.Once the Pa ram e ters are dis played use the INC and DEC keys to scroll up and down through the available parameters. Seeparameters,Section8.0.

B.To edit a selected parameter, press the EDIT key and the ed it ing menus will be come ac tive.

C.Parameters are ei ther a nu meric value (ex am ple: Ef fec tive Area) or con trol a hard ware/operating mode.

7.4Editing of a Hardware/Operating Mode Parameter.

A.If a pa ram e ter con trols a hard ware or op er at ing mode fea ture, use the INC and DEC keys to scroll through the avail able set tings.

B.Af ter the de sired set ting is se lected, press the EDIT key again to save the selected set ting to mem- ory.

C.The LCD will dis play SAVED for approximately 1 sec ond and then redisplay the new set ting.

7.5Editing a Numeric Value Parameter.

A.If the selected pa ram e ter to edit is a nu meric value,

the ed it ing menus will dis play the cur rent value and the cur rent cur sor po si tion for the dec i mal po si tion.

B. Use the INC and DEC keys to in cre ment or dec re- ment the numeric value at the current cursor posi- tion.

C. To change the cursor position press the MODE key. The LCD will display ‘x 1’ if the ones column is to be changed, ‘x 10’ for the tens column, ‘x D1’ for the tenths col umn, ‘x D01’ for the hun dredths col- umn, etc. The number will not in cre ment or dec re- ment if the pa ram e ter limit is reached. See the Chart Below and the examples to the right.

Page 12

MST2000 Multivariable SMARTFLOW ® Transmitter

Brandt Instruments, Inc.

Image 11
Contents MST2000 Series Thermo Brandt Instruments, Inc MST2100, NemaProduct Overview Table of ContentsModel Number Series Loop Powered Multivariable Smartflowtm TransmitterFunctional Specifications SpecificationsDimensions MST2400 Nema 4X Enclosure Mounting and Process ConnectionsContinuous Purge Option MST2100 Nema 1 EnclosureIntegral 5 MicronCoalescentFilter Integral High Pressure Blowdown SystemBal ancing the Purge if the Pro cess is in Op er a tion Bal ancing the Purge if the Pro cess is not in Op er a tionCanadianStandardsAssociationHazardousAreaApprovals Te gral Power Sup ply Op tionElectrical Connections LCD Display and Integral KEY PADStartup MST2000 Operational Modes and Start UPLCD Display Se lect the Pa ram e ter to Edit Editing of a Hardware/Operating Mode ParameterProgramming ProgrammingProgram Parameters LcdconFspan Program Parameters Stdden Tmpsrc Tmpcon Rtdcal Extpz TpzcalApzcal Exaps Extps TpscalAprsrc Aprcon Exapz Outpto ApscalInputo Inputg Dspres OutptgAvgfac DefdspHtenb Pword BdenbHigh Byte ‘BIT’ Definitions Alarm Programming InformationAlarm ‘ENABLE’ Word Definition Low Byte ‘BIT’ DefinitionsAlarm Sta tus ‘BIT’ Def i ni tions Alarm Programming InformationAlarm ‘STATUS’ Word Definition Alarm ‘STATUS’ Word = Alarm ‘ENABLE’ Word Decimal CalculationExamplesLCD Icon, Fail-low, RTD Fault and Under-range Alarm ‘STATUS’ Word Decimal Decode ExamplesMetric Conversion Factors Formulas & Conversion Factors Alarm ‘STATUS’ Word =Formulas & Conversion Factors Scfm = Ae × 23972..677 × DP × P ÷TIsolated 4-20mA Input Mod ules ISO Mod ule Optional Module InstallationTest Jack Is removed for all I.S. and Division 2 approved MST2000’sCalibrating the ISO Module Optional Module InstallationProgramming the MST2000 to recognize the ISO Modules Hart CommunicationsModule Digital Input / Output Module InstallationHart Connections Power and Loop ConditionsMST2000 Hart Communications Information MST2000 Hart Communications InformationHart Communication Distance Power Supply RequirementsPv = primary variable Intrinsic Safety ConsiderationsHart Command Information Power Sup ply & Ab so lute Pres sure Trans mit ter Wiring DiagramsPower Sup ply and Ab so lute Pres sure Trans mit ter Wiring DiagramsDivision 2 And Other Installations MST2000 Hazardous Area InstallationMST2000HazardousAreaInstallation IntrinsicallySafeInstallationsApproved Options MST2000 Hazardous Area Installation15.4 MST2000 I.S. Installation Drawing SC37-4000-00 Output Gain Calibration of the MST2000Output mA Calibration DP Calibration Cal i bra tion of the MST2000

MST2000 specifications

The Tamron MST2000 is a groundbreaking optical device that showcases the company's commitment to innovation and quality in the world of photography and imaging. Designed for both professional photographers and enthusiastic hobbyists, the MST2000 delivers exceptional image quality, versatility, and ease of use.

One of the standout features of the Tamron MST2000 is its superior optical design. It incorporates advanced lens element configurations that minimize aberrations and distortion, ensuring sharp and vibrant images across the entire frame. The lens construction includes high-grade glass elements that enhance light transmission, resulting in crystal-clear images even in low-light conditions. This is particularly beneficial for night photography or indoor settings where lighting may be challenging.

The MST2000 also boasts an impressive zoom range, allowing photographers to capture a wide variety of subjects with ease, from breathtaking landscapes to intimate close-ups. Its robust zoom mechanism enables seamless transitions between focal lengths, helping users to adapt to different shooting environments quickly. The zoom is complemented by a fast and accurate autofocus system that ensures subjects are sharply focused, allowing photographers to capture fleeting moments with confidence.

In terms of build quality, the Tamron MST2000 is constructed with durability in mind. The lens features a weather-sealed body, making it resistant to moisture and dust. This design consideration allows photographers to shoot in diverse conditions without fear of damage, ensuring that the MST2000 is a reliable companion in any situation.

Another notable technology featured in the MST2000 is the vibration compensation system, which helps to reduce the effects of camera shake. This is particularly beneficial when shooting at slower shutter speeds or using longer focal lengths, allowing for clearer images without the need for a tripod.

For those who appreciate creative control, the MST2000 includes various customizable settings that enhance the user experience. Photographers can fine-tune parameters such as focus and aperture easily, providing them with the flexibility to achieve their desired artistic effects.

In summary, the Tamron MST2000 offers a sophisticated combination of advanced optical technologies, versatility, and user-friendly features. Whether capturing sweeping panoramas or intricate details, this lens is designed to meet the demands of today's photographers while inspiring creativity and exploration in every shot.