Ingersoll-Rand 67161-() specifications Remarks, Enter Step Setting Counter Prog

Page 4

PROGRAMMING (continued)

 

PRESS

DISPLAY

REMARKS

STEP

 

 

This section of the menu is used to set Preset B value.

 

 

 

1

 

 

 

SETTING

PROG

 

 

 

 

 

PRESET B

 

#####

This is Preset B. To change, press the arrow key under the

 

 

 

 

 

digit(s) to change. Press ``enter￿ to enter the displayed val7

 

 

 

ue.

 

ENTER

 

 

STEP

 

 

 

2

 

 

 

SETTING

PROG

 

 

 

 

 

SCALING

 

 

This section of the menu is used to set up the scaling factor

FACTOR

 

 

 

 

for the count input.

 

 

 

PROG

 

This sets the decimal for factor A. Press the arrow key under

 

the digit where the decimal is desired. To clear the decimal,

 

press the arrow key furthest to the right.

ENTER

 

#####

This is the scaling factor for the count input. To change,

 

press the arrow key under the digit(s) to change. Press ``en7

 

ter￿ to enter the displayed value.

ENTER

STEP

3

SETTING

THE

COUNTER

PROG

PROG

 

This section of the menu sets up the counter information.

PROG

 

 

Press the ``PROG￿ key to choose ``RST 0￿ (reset to 0, count

or

up) or ``SET PR￿ (set to preset, count down), press the ``en7

 

ter￿ key to enter the displayed choice.

ENTER

 

 

This sets the decimal location for the ``A￿ and ``B￿ counters.

 

Press the arrow key under the desired digit location. To

 

clear the decimal, press the arrow key furthest to the right.

ENTER

Press the ``enter￿ key to enter the displayed location.

 

This section sets the second counter operation. Press the

or

program key to choose ``GR TOT￿ (grand total) or ``BA TOT￿

(batch total). Press the ``enter￿ key to enter the displayed

 

ENTER

choice.

 

Press the ``PROG￿ key to choose ``HIGH CPS￿ (0 7 9.99

or

KHz) or ``LOW CPS￿ (0 7 40 Hz). Press the ``enter￿ key to

 

enter the displayed choice.

ENTER

 

PAGE￿￿4 OF 8

67161￿X

Image 4
Contents Specifications For Diaphragm Pumps System DescriptionWiring AC PowerDiaphragm Pump with Cycle Counter Stage FlowPress to ``start a batching operation if unit is ``reset ProgrammingPress to enter a value in pro Press to enter lock code to Press to ``resume a batch ing operation if one is ``pausedRemarks Enter Step Setting Counter ProgProg Step Prog Setting Rate Step Prog Setting LockPressdisplayremarks EnterStep Prog Setting Relays Dimensional Data 400250 450PAGE8

67161-() specifications

The Ingersoll-Rand 67161-() is a robust and versatile tool pivotal for various industrial and manufacturing applications. Renowned for its durability and high performance, this model is designed to cater to the needs of professionals seeking reliability and efficiency.

One of the main features of the Ingersoll-Rand 67161-() is its advanced air motor technology. The air motor offers superior power-to-weight ratios, allowing operators to achieve high rotational speeds while minimizing fatigue during extended usage. This feature is paramount in settings where precision is necessary, such as assembly lines or heavy machinery maintenance.

The tool is also equipped with an ergonomic design to enhance user comfort. The grip is designed to fit comfortably in the hand, reducing the strain on operators during prolonged use. This thoughtful design consideration helps to increase productivity while diminishing the likelihood of injuries associated with repetitive motion. The lightweight construction further facilitates ease of use in tight spaces or overhead applications.

Ingersoll-Rand integrates cutting-edge materials in the 67161-() model, which enhances its durability and resistance to wear. The construction utilizes high-strength alloys designed to withstand rigorous conditions, making it suitable for industrial environments. This reliability translates into less downtime for maintenance and repairs, contributing to overall operational efficiency.

Another noteworthy characteristic of the Ingersoll-Rand 67161-() is its adjustable torque settings. This flexibility allows users to tailor the tool’s output to the specific requirements of each task, promoting precision and control. Whether it is fastening or loosening bolts, the ability to adjust torque settings ensures that users can maintain the integrity of fasteners without causing damage.

Furthermore, this model features a low decibel rating, which makes it particularly appealing for use in environments where noise control is important. Reducing noise pollution not only creates a more pleasant working environment but also helps in adhering to safety regulations regarding sound exposure.

In summary, the Ingersoll-Rand 67161-() stands out due to its combination of powerful air motor technology, ergonomic design, robust construction, adjustable torque settings, and minimal noise emission. These qualities make it an essential tool for professionals across a range of industries, ensuring that they can rely on its performance to meet their demanding requirements efficiently and safely.