Keating Of Chicago LB-100, PC14 Disassembly, Melt AND/OR Pump Indicator Lights, Melt Cycle Sensor

Page 6

SERVICE

DISASSEMBLY

You will need:

 

Adjustable wrench

“Stubby” screwdriver

Standard pliers

Standard screwdriver

Servicing should only be performed by qualified and licensed service companies. Always disconnect the electrical power cable before attempting any service

The filter maybe hot; use care while servicing. As a safety precaution, it is recommended you drain oil from the filter vessel before performing any servicing.

A. MELT AND/OR PUMP INDICATOR LIGHTS

Removal:

1.Disconnect filter from electrical power source.

2.Feel front end panel from bottom to locate rear of defective indicator light. Note two tangs that extend slightly beyond indicator light barrel diameter. Use a standard pliers to squeeze tangs together and pull indicator light free from panel. If indicator light doesn’t release, squeeze tighter and break barrel to release electrical leads. Discard broken pieces.

Replacement:

1.If necessary, clip off electrical leads as close as possible to indicator light. If leads were clipped, trim off insulation 1/8 inch from end.

2.With electrical leads extending through panel front, press them into recesses at rear of replacement indicator light to secure them in place. Press indicator light into panel until tangs engage to secure indicator light to panel.

B.MELT AND/OR PUMP ON/OFF SWITCH

Removal:

1.Disconnect filter from electrical power source.

2.Unscrew nut securing defective switch to panel. Push switch in to release from panel. Remove nameplate from front of panel.

3.Access to rear of switch through bottom hole under front end panel.

4.Disconnect leads from switch. Tag leads as they are disconnected to assure, during replacement, they are reconnected to the proper switch terminals.

Replacement:

1.Connect tagged electrical leads to replacement switch.

2.Insert replacement switch through panel from which defective switch was removed. Insert nameplate over toggle and secure to panel with nut supplied with switch. Orient switch and tighten nut to secure in desired position.

3.Plug in filter power cord and operate switch to verify switch orientation corresponds to nameplate legend. If not, loosen attaching nut and reorient nameplate and/or switch as desired and retighten nut.

C.MELT CYCLE SENSOR

Removal:

1.Disconnect filter from electrical power source.

NOTE: Remove all oil from filter vessel. Filter must be positioned on its end to access melt cycle sensor.

2.Raise front (power cord) end of filter and rest filter on oil absorbing rags on its back end.

3.Remove bottom cover attaching screws; remove bottom cover.

4.Remove electrical leads from defective melt cycle sensor.

5.Loosen heater element cover attaching nut adjacent to melt cycle sensor sufficiently to release melt cycle sensor and its retaining plate. Disengage melt cycle sensor.

Replacement:

1.Orient replacement melt cycle sensor in its retaining plate such that the metallic sensing surface will be in direct contact with filter vessel. If necessary, reverse orientation of retaining plate.

2.Position retaining plate under heater element and tab on heater element cover with melt cycle sensor sensing surface in direct contact with filter vessel. Tighten loosened heater element attaching nut.

3.Attach removed electrical leads to melt cycle sensor. Verify terminals are not in contact with any metallic parts of filter vessel, heater cover or heater.

4.Secure bottom cover with removed attaching screws.

5.Position filter right-side-up and clean up oil absorbing rags.

4

Image 6
Contents Portable Filter Keep this Manual for Training NEW Personnel Preparing the Portable Filter FiltrationCLEAN-UP Melting Solid ShorteningProblem Probable Cause Preventive MaintenanceMelt AND/OR Pump ON/OFF Switch DisassemblyMelt AND/OR Pump Indicator Lights Melt Cycle SensorHeater Elements Pump and MotorHeat Tape Portable Filter Parts List Parts LB200 Model Page Page Page LB200 1 Way Pump Pump 010567 LB200 2 Way Pump Pump 010567 PC14 Warranty Service Information