0C05 MWL Delivery Delay:

MERLIN LEGEND Communications System Release 7.0

Issue 1

Pocket Reference 555-670-116

 

April 1999

 

 

 

 

 

Reference Documents

 

114

 

 

 

 

 

 

Technical Addendum

 

 

 

Maintenance Error Codes—Continued

 

 

 

 

 

 

Error

 

 

 

Code Description

Action

 

0C04 MWL Fac Timeout:

Two consecutive messages to update Message Waiting lights have been sent across the private network for the same tandem trunk and have not been acknowledged. When this happens three times, the error becomes permanent. The alarm remains in the log until a message is acknowledged or five days pass.

Check the error log for additional error codes. If the error log also contains errors indicating problems with the 100D and/or 400EM module, troubleshoot the 100D and/ or the 400EM module (see Chapter 4 of Maintenance and Troubleshooting).

If the 100D and/or the 400EM module are functioning properly, troubleshoot the trunks using instructions in Chapter 5 of Maintenance and Troubleshooting.

0C05 MWL Delivery Delay:

A message to update the Message Waiting lights has exceeded the time period for delivery. A transient alarm occurs after one minute, and a permanent alarm occurs after 15 minutes. The alarm remains in the error log until a message is delivered or five days pass.

Check the error log for additional error codes. If the error log also contains errors indicating problems with the 100D and/or 400EM module, troubleshoot the 100D and/ or the 400EM module using instructions in Chapter 4 of Maintenance and Troubleshooting. If the 100D and/or the 400EM module are functioning properly, troubleshoot the trunks using instructions in Chapter 5 of Maintenance and Troubleshooting. Check that the system receiving the message had enough TTRs to handle the volume of calls. Check the error log on the sending system and then on the receiving system. More facilities or TTRs may be needed.

1C01

POOL M-BUSY EXCEEDS

Check trunk.

 

50%:

 

 

more than half the trunks in pool

 

 

are busy.

 

1C02

DPR TEST NOT COMPLETED: Slot did not complete initializing.

1C03

FW UPGRADE ATTEMPT:

No action required.

1C04

FW UPGRADE COMPLETE

No action required.

Page 120
Image 120
Lucent Technologies 555-670-116 Technical Addendum, Maintenance Error Codes-Continued, 0C05 MWL Delivery Delay, 1C01, 1C02