MERLIN LEGEND Communications System Release 7.0 | Issue 1 |
Pocket Reference | April 1999 |
|
|
Control Unit Interfaces | 37 |
|
|
—The 145D protector provides AC surge protection for the entire system, including the power supply module. One unit provides protection for six outlets.
—The 146C protector provides Central Office (CO) line surge protection. One unit covers four CO lines.
Complete installation instructions are provided with the surge protectors.
Control Unit Interfaces
|
| Signaling | Audio/ |
|
| Channel | Data |
Interface Applications | Rate | Rate | |
BRI S/T1 Control unit to MLX telephone | 16 kbps (D) |
| |
|
| 64 kbps (B) |
|
| ISDN Terminal Adapter | 64 kbps (B) |
|
|
| and (D) |
|
DS1 | Control unit to the following services: | 64 kbps |
|
T1
Emulated tie trunk
Emulated DID
Emulated
Emulated
PRI services
ACCUNET®switched digital service
MEGACOM®WATS
MEGACOM 800
Software Defined Network (SDN)
MultiQuest®900 number services
Connectivity to 5ESS Generic 6/7/8/FTS 2000
Multiple incoming calls to directory number
Password handling for FTS 2000
2400 bps | 2400 bps | ||
| system programming port | or | or |
|
| 1200 bps | 1200 bps |
| Control unit to Lucent Technologies model | 1200 bps | 1200 bps |
| 572 printer, PC with CAS, or CAT connected |
|
|
| to |
|
|
ATL | Control unit to analog multiline telephone | 40kHz | 300– |
|
|
| 3400 Hz |
Tip/Ring | Control unit to | 40kHz | 300– |
| telephone, modem, fax, OPT, or |
| 3400 Hz |
| voice mail system |
|
|
ETR | Control unit to ETR telephone | 40kHz | 300– |
| or MLS telephone |
| 3400 Hz |
1 Call handling derived from CCITT recommendation Q.931.