MERLIN LEGEND Communications System Release 7.0 | Issue 1 |
Pocket Reference | April 1999 |
|
|
Hardware and Software Capacities | 39 |
|
|
Hardware and Software Capacities
You can configure the system as a
—Up to 108 simultaneous
NOTE:
If more than 108 conversations are in progress at the same time, blocking can occur.
—Up to 80 line/trunk jacks, including
—Up to 400 extension endpoints that support a combination of the following:
—Up to 272 physical extension jacks for telephones and adjuncts
—Up to 200 logical digital data ports (through ISDN terminal adapters connected to jacks on the MLX module) providing
—System
—Up to three 100D DS1 modules, maximum two per carrier; the 24 channels on each 100D DSI module count toward the 80 line/trunk capacity
—Up to five 800
—One CTI link when operating in Hybrid/PBX mode
The system has a total capacity of 352 physical jacks (80 outside lines/trunks plus 272 extensions); however, each MLX module extension jack supports two logical endpoints (extension devices that can operate simultaneously and independently of each other). For example, an MLX telephone with a
Similarly, although the 100D module has only one jack, it can serve up to 24 endpoints (emulated lines/trunks or PRI lines/trunks). Thus, you can configure the system to connect up to 80 lines/trunks and 400 extension
The next table, Hardware and Software Capacities, lists the hardware and software capacities of the system. Constraining Factors appear with a checkmark (✓) and are explained at the end of the table.