Download 153 pages 53.93 Kb
Page 123
Image 123
6C07

MERLIN LEGEND Communications System Release 7.0

Issue 1

Pocket Reference 555-670-116

 

April 1999

 

 

 

 

Reference Documents

 

117

 

 

 

 

 

 

Technical Addendum

 

 

Maintenance Error Codes—Continued

 

 

 

 

 

 

Error

 

 

 

Code Description

Action

 

6C06 DS1 REMOTE MULTIFRAME:

Far end of network interface is experiencing loss of multiframe; service on link has been lost.

Usually no action. Check T1 facility. If problem persists, contact NSAC Tier III.

6C07

DS1 MAJOR ALARM:

Usually no action. Check T1

 

Average bit error rate exceeds

facility. If problem persists,

 

contact NSAC Tier III.

 

10E-3; service on link has been

 

MaintenanceSlot

 

lost.

 

Error Events

 

 

 

 

Current hr

6C08

DS1 MINOR ALARM:

Usually no action. Check T1

 

Average bit error rate exceeds

facility. If problem persists,

 

contact NSAC Tier III.

 

10E-6.

 

MaintenanceSlot

 

 

 

 

Error Events

 

 

Current hr

6C09

DS1 MISFRAME ALARM:

Usually no action. Check T1

 

Misframe count reached 18.

facility. If problem persists,

 

contact NSAC Tier III.

 

 

 

 

MaintenanceSlot

 

 

Error Events

 

 

Current hr

6C0A

DS1 SLIP ALARM:

Usually no action. Check T1

 

Slip count reached 88.

facility. If problem persists,

 

contact NSAC Tier III.

 

 

 

 

MaintenanceSlot

 

 

Error Events

 

 

Current hr

6C0B

HARDWARE INOPERATIVE:

A Busy-Out/Restore or Reset/

 

Hardware not operating properly.

Restore may clear problem. If

 

If this is the only 100D module or

problem persists, contact NSAC

 

800 NI-BRI module, or if this is the

Tier III.

 

designated clock module, its tdm

 

 

bus clock generator was not

 

 

activated.

 

6C0C

BRI LOSS OF SYNC:

Usually none; check BRI facility.

 

Service on link has been lost.

If problem persists, contact

NSAC Tier III.

6C0D BRI SLIPS > 88:

Slip count > 88. Service on link is still operative.

Usually none; check BRI facility. If problem persists, contact NSAC Tier III.

6C0E BRI NET REQUESTED CCRCs:

Outgoing signal to the network does not have valid framing information. Service on link is still operative.

Usually none; link should return to normal once test is completed. If problem persists, contact NSAC Tier III.

6C0F BRI NET DEACTIVATE:

Layer 1 of the link is down. Service on link has been lost.

Usually none; link should return to normal once test is completed. If problem persists, contact NSAC Tier III.