Constraining Factors

43

Primary and secondary delay announcements per system. With

 

Release 5.0 and later systems, up to 10 primary and one secondary

 

announcement device can be designated for each calling group.

 

Each announcement device decreases the 200 tip/ring station

 

capacity.

 

Carriers

 

The first slot of the basic carrier is used for the processor module,

 

with a maximum of 5 port/board slots.

 

Coverage Groups

 

Senders per group. QCCs cannot be senders because they do not

 

have coverage available and use Position-Busy instead.

 

CTI Link

 

One CTI link is supported in Hybrid/PBX mode only.

 

Fax Machines with Message Waiting

 

The system can support more than 16 fax machines, but those in

 

excess of 16 cannot use fax message waiting indication.

 

Ports (not simultaneously)

 

Voice Messaging Interface. Although the system software supports

 

up to 24 VMI ports, all VMI ports must be in the same calling group,

 

and the maximum number of extensions in a calling group is 20.

 

Service Observing Groups

 

A Service Observer station must be an MLX telephone (except QCC

 

or CTI link). A Service Observing group member station can be any

 

telephone except QCC or CTI link. The maximum number of

 

members per Service Observing group is equal to the maximum

 

number of extensions in the system.

 

NOTE:

 

Service Observing may be subject to federal, state, or local

 

laws, rules, or regulations or require the consent of one or

 

both of the call parties. You must check in your jurisdiction and

 

comply with all applicable laws, rules, and regulations before

 

using this feature. Failure to comply may result in severe

 

penalties.

 

Speed Dial

 

Personal Speed Dial. Single-line and 5- or 10-button telephones.

 

System Operator Consoles

 

DLCs. Two consoles are allowed for each 408 MLX, 008 MLX, or

 

analog multiline module, and four consoles are allowed for each 016

 

MLX module (Release 7.0 and later). A maximum of eight DLC

 

consoles are allowed per system. Up to two DSSs can be attached

 

to an MLX operator console, and one is built into the MERLIN II

 

System Display Console.

 

QCCs. Two consoles are allowed for each 408 MLX or 008 MLX

 

module, and four consoles are allowed for each 016 MLX module

 

(Release 7.0 and later). A maximum of four QCC consoles are

 

allowed per system.

 