Constraining Factors | 43 |
Primary and secondary delay announcements per system. With |
|
Release 5.0 and later systems, up to 10 primary and one secondary |
|
announcement device can be designated for each calling group. |
|
Each announcement device decreases the 200 tip/ring station |
|
capacity. |
|
Carriers |
|
The first slot of the basic carrier is used for the processor module, |
|
with a maximum of 5 port/board slots. |
|
Coverage Groups |
|
Senders per group. QCCs cannot be senders because they do not |
|
have coverage available and use |
|
CTI Link |
|
One CTI link is supported in Hybrid/PBX mode only. |
|
Fax Machines with Message Waiting |
|
The system can support more than 16 fax machines, but those in |
|
excess of 16 cannot use fax message waiting indication. |
|
Ports (not simultaneously) |
|
Voice Messaging Interface. Although the system software supports |
|
up to 24 VMI ports, all VMI ports must be in the same calling group, |
|
and the maximum number of extensions in a calling group is 20. |
|
Service Observing Groups |
|
A Service Observer station must be an MLX telephone (except QCC |
|
or CTI link). A Service Observing group member station can be any |
|
telephone except QCC or CTI link. The maximum number of |
|
members per Service Observing group is equal to the maximum |
|
number of extensions in the system. |
|
NOTE: |
|
Service Observing may be subject to federal, state, or local |
|
laws, rules, or regulations or require the consent of one or |
|
both of the call parties. You must check in your jurisdiction and |
|
comply with all applicable laws, rules, and regulations before |
|
using this feature. Failure to comply may result in severe |
|
penalties. |
|
Speed Dial |
|
Personal Speed Dial. |
|
System Operator Consoles |
|
DLCs. Two consoles are allowed for each 408 MLX, 008 MLX, or |
|
analog multiline module, and four consoles are allowed for each 016 |
|
MLX module (Release 7.0 and later). A maximum of eight DLC |
|
consoles are allowed per system. Up to two DSSs can be attached |
|
to an MLX operator console, and one is built into the MERLIN II |
|
System Display Console. |
|
QCCs. Two consoles are allowed for each 408 MLX or 008 MLX |
|
module, and four consoles are allowed for each 016 MLX module |
|
(Release 7.0 and later). A maximum of four QCC consoles are |
|
allowed per system. |
|