Lucent Technologies 555-670-116 Technical Addendum, Maintenance Error Codes-Continued, Issue

Models: 555-670-116

1 153
Download 153 pages 53.93 Kb
Page 128
Image 128
840D INCORRECT FIRMWARE STATE:

MERLIN LEGEND Communications System Release 7.0

Issue 1

Pocket Reference 555-670-116

 

April 1999

 

 

 

 

 

Reference Documents

 

122

 

 

 

 

 

 

Technical Addendum

 

 

 

Maintenance Error Codes—Continued

 

 

 

 

 

 

Error

 

 

 

Code Description

Action

 

840B NO LOOP CURRENT:

Communication problems between module and CO; no loop current. If error occurs four times consecutively and if automatic maintenance-busy is enabled and maintenance-busy limit is less than 50%, trunk is busied-out automatically.

Replace module with similar module and test. If problem is resolved, replace bad module. If problem persists, reinstall old module and test trunk.

840C STUCK RINGING:

Communication problems between module and CO; no loop current. If error occurs four times consecutively and if automatic maintenance-busy is enabled and maintenance-busy limit is less than 50%, trunk is busied-out automatically.

Replace module with similar module and test. If problem is resolved, replace bad module. If problem persists, reinstall old module and test trunk.

840D INCORRECT FIRMWARE STATE:

If error occurs four times consecutively and if automatic maintenance-busy is enabled and maintenance-busy limit is less than 50%, trunk is busied-out automatically.

Turn power off for at least one second, and then turn it on. Repeat system programming procedure. If problem persists, replace module.

840E UPLINK MESSAGE ERROR:

Communication problems between processor and modules. Module received unrecognized message from processor.

Turn processor off and then on. Repeat system programming procedure. If problem persists, replace module.

840F LOST IDLE MESSAGE ERROR:

Loop start trunk lost an idle message during glare timing.

System has taken corrective action. If problem persists, contact NSAC Tier III.

8C01

SLOTS NOT EQUAL:

Check slot descriptions in

 

Module that occupies indicated

backup file against actual

 

system modules that occupy

 

slot does not match slot

 

slots. After mismatch is

 

information contained in PC or

 

corrected, restore.

 

PCMCIA card backup file.

 

 

9801

MCARD WRITE ERROR:

Reset card and try again. If

 

Write to memory card is

problem persists, replace card

unsuccessful or too slow.

and try again. If problem

continues, replace processor

 

 

module.

9802 MCARD ERASE ERROR:

Erasure of memory card is unsuccessful or too slow.

Reset card and try again. If problem persists, replace card and try again. If problem continues, replace processor module.

Page 128
Image 128
Lucent Technologies 555-670-116 manual Technical Addendum, Maintenance Error Codes-Continued, 840D INCORRECT FIRMWARE STATE