MERLIN LEGEND Communications System Release 7.0 | Issue 1 | ||
Pocket Reference |
| April 1999 | |
|
|
|
|
Reference Documents |
| 119 | |
|
|
|
|
|
| Technical Addendum |
|
| Maintenance Error |
| |
|
|
|
|
| Error |
|
|
| Code Description | Action |
|
7401 TRK UPLINK MESSAGE ERROR:
Communication problems between processor and modules; unrecognized message from module to processor.
Test trunk with
7402 LOOP CONTROL BIT NOT SET:
No loop current on outgoing call. If error occurs four times consecutively, and if automatic
Test trunk with
7403 NO LOOP CURRENT:
Communication problems between module and CO. No loop current. If error occurs four times consecutively, and if automatic
Test trunk with
7404 STUCK RINGING:
Communication problems between module and CO. If error occurs two times consecutively, trunk is
Test trunk with
7801 NOT IN NORMAL OP MODE:
Module not in normal operation mode; reported in background module check.
Reset board. If problem persists, check module. Maintenance→Slot→ Slot Number→Reset
7802 | SANITY INT NOT | Reset board. If problem |
| GENERATED: | persists, check module. |
|
| |
| Applies only to modules with |
|
| extension jacks. |
|
7803 | NO PORT BOARDS | None; delete entry from |
| AVAILABLE: | transient log. |
|
| |
| Modules not present. |
|
7804 | INVALID SANITY | Reset board. If problem |
| RESPONSE: | persists, check module. |
|
|
Sanity test received invalid responses; applies only to modules with extension jacks.