Control Unit Modules—Continued

MERLIN LEGEND Communications System Release 7.0

Issue 1

Pocket Reference 555-670-116

April 1999

 

 

 

 

Ordering Codes

 

74

 

Control Unit Modules—Continued

 

 

Module

Trunk Type

Extension Type

 

 

100D1

T1 or PRI

T1 emulates 24 lines/trunks: loop-start,

 

 

 

 

ground-start, tie, and Direct Inward Dial

 

 

 

 

(DID; Hybrid/PBX mode only); can also

 

 

 

 

supply subscriber services. In Release 4.0

 

 

 

 

and later, T1 can also provide high-speed

 

 

 

 

(56K) data communications and digitally

 

 

 

 

emulated tie trunks for data

 

 

 

 

communications. PRI supports subscriber

 

 

 

 

services, allows high-speed digital data

 

 

 

 

communications, and includes special

 

 

 

 

features.

 

 

400 LS2

Loop-start

1 PFT telephone

 

 

 

and TTR

 

 

 

 

 

 

 

 

400EM

Tie trunk

N/A

 

400 GS/LS

Loop-start or

 

ground-start

 

and TTR

PFT telephone (button needed for ground-start PFT telephone)

408

(LS-ATL)2

Loop-start

Analog multiline telephones; CMS; 1 PFT

 

 

 

telephone

 

 

 

 

408

GS/LS

Loop-start or

Analog multiline telephones; CMS; 1 PFT

 

 

ground-start

telephone with GS button

1For newer vintages of this module, firmware can be upgraded by using a PCMCIA card.

2Although this MERLIN®II modules is supported, the following are recommended for the system: 400 GS/LS, 408 GS/LS, 408 GS/LS-MLX, 800 GS/LS, and 800 GS/LS-ID.