Technical Addendum

MERLIN LEGEND Communications System Release 7.0

Issue 1

Pocket Reference 555-670-116

 

April 1999

 

 

 

 

 

Reference Documents

 

112

 

 

 

 

 

 

Technical Addendum

 

 

 

Maintenance Error Codes—Continued

 

 

Error

 

 

 

Code Description

Action

 

0010 INVALID SLOT INTERRUPT:

Cannot determine module responsible for interrupt.

Check modules and replace if necessary; if problem persists, check processor.

0011

STACK OVERFLOW:

Check processor.

 

Processor problem.

 

0012

INVALID RESET FLAG:

Check processor.

 

Processor problem.

 

0013

DUART STREAMING INT:

Check processor.

 

Processor problem.

 

0014

PROCESSOR ERR

Check processor.

 

INTERRUPT:

 

 

Processor problem.

 

0015

MODULE MISMATCH:

Change system

 

Module inserted into wrong slot.

programming for proper module

 

or install proper module.

 

 

0016

POWER UP COLD START:

If problem persists, check

 

Module dual port ram failure;

module for slot indicated.

 

system programming OK.

 

0017

REAL TIME CLOCK FAULT: If problem persists, replace

 

Date and/or time incorrect or

processor module.

 

 

 

unreadable.

 

0018

RTC COLD START:

 

 

This error is not displayed.

 

0019 RESET TIME & DATE:

System cold-starts because real- time clock chip is not working correctly.

If problem persists, replace processor module.

0401 ABK CARD NOT INSERTED: Insert a translation card or an

PCMCIA memory card for

unformatted card.

translation is not inserted.

 

0402 ABK INCORRECT CARD TYPE:

PCMCIA memory card for non- translation is inserted.

Remove current card and insert a translation card or an unformatted card.

0403

ABK CARD WRITE-

Turn write-protection switch to

 

PROTECTED:

off. If problem persists, try

 

another card. If still not working,

 

Translation card has write-

 

replace processor module.

 

protected switch on.

 

 

0404

ABK EXTENSION BUSY:

Wait until station changes

 

A station is in program,

mode.

 

 

administration, or maintenance mode.

Page 118
Image 118
Lucent Technologies 555-670-116 manual Technical Addendum, Maintenance Error Codes-Continued, Invalid Slot Interrupt, Issue