SCO OpenServer 5 error messages

Error message

Reason

Action required

 

 

 

 

ERROR: unit @0xnnnnnnnn has

Incorrectly installed or faulty

1.

Ensure that you have followed the

bad resource(s)

card.

 

installation procedure correctly.

 

Incorrect BIOS settings.

 

See page 45.

 

2.

Check BIOS settings.

 

 

 

 

3.

If the problem persists try another card.

 

 

 

See page 45 and page 94.

ERROR: unit @0xnnnnnnnn not

Insufficient memory available

Reconfigure system/kernel memory

mapped

to kernel.

parameters.

ERROR: unit @0xnnnnnnnn not

Incorrectly installed or faulty

1.

Ensure that you have followed the

initialised

card.

 

installation procedure correctly.

 

 

 

See page 45.

 

 

2.

If the problem persists try another card.

 

 

 

See page 45 and page 94.

WARNING: unit @0xnnnnnnnn not

System error.

1.

Uninstall the driver and remove all

configured

 

 

Speed cards from the system.

 

 

 

See page 60

 

 

2.

Re-install the driver and cards taking

 

 

 

care to follow the correct procedure.

 

 

 

See page 45 and page 94.

WARNING: No Speed ports

No cards installed.

1.

Install cards. See page 94.

configured

Installed cards suffer from

2.

Resolve any above listed faults.

 

 

one or more of above

 

 

 

symptoms.

 

 

 

 

 

 