1C06 BAD BOARDS IN SYSTEM:

MERLIN LEGEND Communications System Release 7.0

 

Issue 1

Pocket Reference 555-670-116

 

 

April 1999

 

 

 

 

 

Reference Documents

 

115

 

 

 

 

 

 

 

Technical Addendum

 

 

 

Maintenance Error Codes—Continued

 

 

 

 

 

 

 

 

Error

 

 

 

 

Code Description

Action

 

 

1C05 INVALID FMW 29

DETECTED:

Incompatibility problem; specified video endpoint or UDM is connected to an 008 or 408 MLX module with firmware of vintage 0x29.

Replace 008 or 408 MLX module with one of another firmware vintage. Retire permanent alarm manually.

1C06 BAD BOARDS IN SYSTEM:

At least one incompatibility problem of type HER 0x1C05 detected. Turns on red LED on processor.

Replace 008 or 408 MLX module with one of another firmware vintage. Retire permanent alarm manually.

1C07

See error code 0801

2C01

T1 ACCESS VIOLATION: Check facility provisioning and re-

T1 services (channels-voice/

administer channels for voice or

data. Ensure that T1 data facilities

data) programmed incorrectly.

are accessed from data terminals

 

 

only (such as UDMs or desktop

 

video systems) and that T1 voice

 

facilities are accessed from

 

telephones only (such as MLX

 

telephones).

2C02 Bearer Capability Incompatibility:

A64 kbps clear-channel data call was routed to a facility that does not have sufficient bandwidth to handle the call.

Verify that the ARS or UDP routing tables route a data call to a DS1 facility. Check the DS1 Type administration item for the specified facility. If the programmed value is T1, the caller must initiate a 56 kbps call. Check the DS1 Suppression administration item for the specified facility. If the programmed value is AMI-ZCS, the caller must initiate a 56 kbps call.

3001

ALARM TABLE FULL:

Correct indicated errors, and then

 

error logs are full; turns on

remove entries from the transient

 

system error log. If problem

 

processor led.

 

persists, cold-start the system.

 

 

 

 

SysProgramSystem

 

 

Restart

4401

USER REQUESTED SYS

If error remains in transient log,

 

ERASE:

repeat System Erase. If problem

 

persists, check processor.

 

Logged after System Erase. If

 

 

 

System Erase is successful, this

 

 

error is removed immediately.

 

4402

USER REQST

None.

 

UPGRD/INSTALL:

 