MERLIN LEGEND Communications System Release 7.0

Issue 1

Pocket Reference 555-670-116

 

April 1999

 

 

 

 

 

Reference Documents

 

116

 

 

 

 

 

 

Technical Addendum

 

 

 

Maintenance Error Codes—Continued

 

 

 

 

 

 

 

 

Error

 

 

 

 

 

Code

Description

Action

 

 

4C01

POOL EMPTY:

Replace boards.

 

System needed to use a trunk in a pool but no trunks were physically present in the pool— i.e., all of the boards were removed from the system.

4C02

POOL BUSY:

 

 

System needed to use a trunk in

 

 

a pool. Trunks are physically

 

 

present; however, none are idle

 

 

and available for use—i.e., they

 

 

may be in use or out of service.

 

4C03

POOL BUSY &/OR OOS:

Restore if out of service.

 

System needed to use a trunk in

 

 

a pool. Trunks are physically

 

 

present; some may be busy but

 

 

some are idle. However, the idle

 

 

trunks are not in service.

 

5801

See error code 0801

 

5802

Board Renumber

If the system is functioning

Board renumber took place.

properly, simply remove the error

from the Transient Error Log. If the

 

 

system is not functioning properly,

 

check the Transient Error Log to

 

verify that a board renumber took

 

place. Then compare the system’s

 

previous configuration to the one

 

after board renumbering to

 

determine if the board renumber

 

caused logical IDs to shift.

6C01 DS1 LOSS OF SIGNAL ALARM:

Service on link has been lost.

Usually no action. Check T1 facility. If problem persists, contact NSAC Tier III.

6C02 DS1 BLUE ALARM:

All 1s being received; service on link has been lost.

Usually no action. Check T1 facility. If problem persists, contact NSAC Tier III.

6C03 DS1 RED ALARM:

Invalid framing information on incoming signal; service on link has been lost.

Usually no action. Check T1 facility. If problem persists, contact NSAC Tier III.

6C04 DS1 YELLOW ALARM:

Far end of network interface has lost frame synchronization; service on link has been lost.

Usually no action. Check T1 facility. If problem persists, contact NSAC Tier III.

6C05 DS1 LOSS OF MULTIFRAME:

Service on link has been lost.

Usually no action. Check T1 facility. If problem persists, contact NSAC Tier III.