MERLIN LEGEND Communications System Release 7.0

Issue 1

Pocket Reference 555-670-116

 

April 1999

 

 

 

 

 

Reference Documents

 

111

 

 

 

 

 

 

 

 

Technical Addendum

 

 

Maintenance Error Codes

 

 

 

Error

 

 

 

 

 

Code

Description

Action

 

0001

TIMEOUT COLD START:

No action required; however, if

 

 

 

System programming OK.

problem persists, troubleshoot

 

 

 

the processor.

 

 

 

 

 

 

0002

POWER UP WARM START:

No action required; however, if

 

 

 

System programming OK.

problem persists, troubleshoot

 

 

 

the processor.

 

 

 

 

 

 

0003

SOFTWARE COLD START:

If problem persists, troubleshoot

 

 

 

System programming OK.

the processor.

 

 

 

 

 

0004

SOFTWARE WARM START:

If problem persists, troubleshoot

 

 

 

System programming OK.

the processor.

 

 

 

 

 

0005

Reset - DIAGNOSTIC

 

 

 

 

SWITCH:

 

 

0006

INCOMPLETE COLD START: If problem persists, troubleshoot

 

 

 

System cold-started while

the processor.

 

 

 

 

 

 

 

restart in progress.

 

 

0007

SANITY TIMEOUT RESET:

Check module and/or

 

 

 

Faulty software, module, carrier,

processor.

 

 

 

 

 

 

 

or processor sanity timer.

 

 

0008

MAX RESET COUNT

If problem persists, troubleshoot

 

 

 

EXCEEDED:

the processor.

 

 

 

 

 

 

 

System cold-started because of

 

 

 

 

too many warm starts.

 

 

0009

FRIGID START:

If processor was removed while

 

 

 

System restarted and initialized to

in use, system may perform

 

 

 

defaults; also logged after System

frigid start because of loss of

 

 

 

Erase.

system programming. Restore

 

 

 

system as described in System

 

 

 

 

 

 

 

 

 

 

Programming and Maintenance

 

 

 

 

 

(SPM).

 

 

000A

POWER UP COLD START:

If problem persists, check

 

 

 

RAM failure in processor; system

processor.

 

 

 

programming OK.

 

 

 

000B

CARD

None.

 

 

 

INSERTED/REMOVED:

 

 

 

000C

SLOT STREAM CNT

If problem persists, check

 

 

 

EXCEEDED:

module.

 

 

 

 

 

 

 

Slot generated excessive

 

 

 

 

interrupts.

 

 

 

000D

FMWR NOT IN STANDBY

If problem persists, check

 

 

 

MODE:

module.

 

 

 

 

 

 

 

Module firmware not in standby

 

 

 

 

mode.

 

 

 

000E

COMMAND BUFFER FULL:

If problem persists, check

 

 

 

 

 

processor and module.

 

 

000F

TASK RUNNING TOO LONG

None; if problem persists, check

 

 

 

 

 

processor.

 

Page 117
Image 117