Jackson TEMPSTAR GPX Electrical Schematics, Tempstar GPX 115 Volt 50/60 Hertz Single Phase

Page 59

SECTION 7: ELECTRICAL SCHEMATICS

TEMPSTAR GPX 115 VOLT - 50/60 HERTZ - SINGLE PHASE

Tempstar/HH GPX Series Technical Manual 7610-002-57-32

Issued: 07-24-2006

Revised: N/A

54

 

Image 59
Contents August 6 7610-002-57-32 Revision D Technical ManualPage Revision Made Applicable Details Date ECN Nomenclature for the Models Covered in this Manual Tempstar HH GPXTable of Contents Section Specification Information Specification Information Selection D Operating Cycle Seconds Selection aSelection B Selection CDimensions for Tempstar GPX Specification InformationALL Dimensions are +/- 1/2 DUE to Adjustable Feet Dimensions for Tempstar HH GPXTable Dimensions Section INSTALLATION/OPERATION Instructions Installation Instructions INSTALLATION/OPERATION InstructionsINSTALLATION/OPERATION Instructions INSTALLATION/OPERATION Instructions GAS Booster Heater Connections DishmachineOperation Instructions INSTALLATION/OPERATION Instructions Section Preventative Maintenance Preventative Maintenance Section Troubleshooting Common Problems TroubleshootingProblem Rinse water not reaching required temperature Section Service Procedures Time Required Service ProceduresPreparation Tools RequiredRemove the wire nuts from the wires and separate them Removing the valve bonnet Special Parts After Maintenance ActionsPreparation Steps Vacuum Breaker Repair Parts KITRemoving the plunger Section Parts Section Parts Section Tempstar GPX Control BOX AssemblyQTY Description Tempstar HH GPX Control BOX Assembly Bracket, Electrical Box Mounting Item QTY Description Tempstar GPX Hood AssemblyTempstar HH GPX Hood Assembly Frame Assemblies TUB Assembly Model Volts Phase Wash Motor Assembly Cantilever ARM/DOOR Assemblies Tempstar GPX Cantilever Arm Cantilever ARM/DOOR Assemblies Tempstar HH GPX Screw, 1/4-20 x 1 1/2 Long Hex Head Inlet Plumbing Assemblies Rinse Header Plumbing Assembly Recirculating Plumbing Assembly Rinse Solenoid Valve & Vacuum Breaker Repair Parts Kits 1911 Wash & Rinse ARM/MANIFOLD Assemblies Tempstar GPXExploded View Wash & Rinse ARM/MANIFOLD Assemblies Tempstar HH GPX Positioning Bracket, Manifold Tube Parts Section Coil AssemblyExhaust FAN Control OPTION/SAFETY Door Interlock SDI Option False panel positioned in unit Tempstar GPX False Panel InstallationTempstar HH GPX False Panel Installation To Cold Water Supply Drain Quench AssemblySection Electrical Schematics Tempstar GPX 115 Volt 50/60 Hertz Single Phase Electrical SchematicsTempstar GPX 208-230 Volt 50/60 Hertz Single Phase Tempstar HH GPX 115 Volt 50/60 Hertz Single Phase Tempstar HH GPX 208-230 Volt 50/60 Hertz Single Phase Exhaust FAN Control OPTION/SAFETY Door Interlock SDI Option

TEMPSTAR HH GPX, TEMPSTAR GPX specifications

The Jackson TEMPSTAR GPX and TEMPSTAR HH GPX are two remarkable models in the world of personal watercraft, combining cutting-edge technology with unmatched performance and versatility. Designed to cater to a wide range of riders, these models are engineered for both adventure and leisure on the water.

One of the standout features of the TEMPSTAR GPX is its powerful engine, which delivers impressive acceleration and top speed. The PWC is equipped with a high-performance engine that not only maximizes horsepower but also optimizes fuel efficiency. This balance ensures that riders can enjoy prolonged adventures without the constant need to refuel.

The TEMPSTAR HH GPX, on the other hand, offers enhanced stability and control, making it an excellent choice for beginners and experienced riders alike. This model boasts an extended hull design that improves tracking and maneuverability, allowing for smooth navigation even in choppy water conditions. The innovative hull design also contributes to a more comfortable ride, reducing the impact of waves and enhancing overall stability.

One of the key technologies featured in both models is the advanced onboard digital display. This feature provides riders with real-time data on speed, fuel consumption, and engine performance. Additionally, the intuitive interface allows for easy navigation through menu options, offering a seamless user experience. For those who love to personalize their rides, these models come with customizable settings, allowing riders to adjust various features to suit their preferences.

Safety is a paramount consideration in the design of the TEMPSTAR GPX and TEMPSTAR HH GPX. Both models are equipped with an array of safety features, including a reliable engine shut-off system and a reinforced safety grab handle. Furthermore, the boats comply with rigorous safety standards to ensure peace of mind for riders and passengers.

In terms of comfort, both models come with ample storage space, allowing riders to stow away essentials for a day on the water. Ergonomically designed seating ensures that passengers can relax for hours, while the strategically placed footwells provide additional comfort during long rides.

Overall, the Jackson TEMPSTAR GPX and TEMPSTAR HH GPX embody a perfect blend of power, technology, safety, and comfort. Whether you're looking for thrilling speed on the open water or a leisurely cruise with friends and family, these models offer a reliable and enjoyable riding experience for enthusiasts of all skill levels.