Keating Of Chicago Miraclean Introduction, Installation Instructions, First Steps

Page 3

INTRODUCTION

Instructions in this manual should be read thoroughly before attempting to operate this Miraclean® Griddle. All installation and service on Keating equipment must be performed by qualified, certified, licensed and/or authorized installation or service personnel.

Service information for Keating equipment has been prepared for use by qualified and/or authorized personnel.

Keating equipment is made in the U.S.A. and has American sizes of hardware. All metric conversions are approximate.

INSTALLATION INSTRUCTIONS

Proper installation will assure top performance. Alteration to your equipment will void the warranty. Before uncrating, check equipment carefully for damage.

IF EQUIPMENT ARRIVES

DAMAGED

Keating does not assume responsibility for loss or damage incurred in transit.

IMPORTANT

This merchandise has been thoroughly inspected and carefully packed before leaving our plant. Responsibility for its safe delivery was assumed by the carrier at the time of shipment. Claims for loss or damage to the contents should, therefore, be made upon the carrier, as follows:

CONCEALED LOSS OR DAMAGE

Concealed loss or damage means loss or damage which does not become apparent until the merchandise has been unpacked. The contents may be damaged in transit due to rough handling even though the carton may not show external damage. When the damage is discovered upon unpacking, make a written request for inspection by the carrier’s agent within fifteen days of the delivery date. Then file a claim with the carrier since such damage is the carrier’s responsibility. By following these instructions carefully, we guarantee our full support of your claims to protect you against loss from concealed damage.

VISIBLE LOSS OR DAMAGE

Any external evidence of loss or damage must be noted on the freight bill or express receipt, and signed by the carrier’s agent. Failure to adequately describe such external evidence of loss or damage may result in the carrier refusing to honor a damage claim. The form required to file such a claim will be supplied by the carrier.

DO NOT RETURN DAMAGED MERCHANDISE TO KEATING FILE YOUR CLAIM AS ABOVE.

FIRST STEPS

POSITIONING

Keep appliance area free and clear of any combustibles. Position the Miraclean® Griddle 6 inches (152mm) from any combustible material. A minimum of 24 inches (610mm) should be provided at the front of the Miraclean® Griddle for servicing and proper operation. Air for combustion enters the Miraclean® Griddle from the bottom of the cabinet and the bottom of the control panel.

DO NOT BLOCK BOTTOM OF MIRACLEAN

GRIDDLE CABINET. DO NOT OBSTRUCT FLUE.

Your Miraclean® Griddle is designed to be serviced from the front with adequate clearance for air openings into the combustion chamber servicing and operation.

MINIMUM CLEARANCE

Suitable for non-combustible floors.

Clearances

Combustible

Non-combustible

 

Construction

Construction

Back

6"

0"

Right Side

6"

0"

Left Side

6"

0"

 

 

 

VENTILATION

The Miraclean® Griddle must be installed in an area providing adequate air supply and ventilation. Do not obstruct the flow of combustion and ventilation air. Proper ventilation is one of the important considerations for efficient operation of the Miraclean® Griddle. It should be installed so that the products of combustion are removed efficiently without producing drafts that will interfere with proper burner operation. The area around the front and bottom of the Miraclean® Griddle must be kept clear and unobstructed. In the U.S.A. the ventilation systems must conform to the ANSI/NFPA96 latest edition. “A minimum of 18" (457mm) should be maintained between the flue outlet and the lower edge of the grease filters.” It is the responsibility of the owner and the local installer to comply with national and local codes.

NATIONAL CODE REQUIREMENT

The installation must conform with local codes, or in the absence of local codes, with the National Fuel Gas code, ANSI Z223.1 or the Natural gas Installation Code, CAN/CGA-B49.1 or the Propane Installation Code, CAN/CGA-B149.2. Keating equipment is designed and manufactured to operate only on the type of gas specified by the user and indicated on the serial plate located on the front panel. The gas may be natural, propane or manufactured. The type of gas cannot be converted to another gas fuel by turning or engaging a switch.

NOTE: NOT FOR OUTDOOR INSTALLATION

1

Image 3
Contents Miraclean GAS Griddle For Your Safety First Steps Installation InstructionsIntroduction If Equipment Arrives DamagedLeveling Flexible GAS Connectors and Quick Disconnect DevicesGAS Connections and Pipe Size Restraining DevicesPlacing Miraclean Griddle in Operation Lighting Instructions Miraclean Griddle Cooking with Your Miraclean GriddleCooking Instructions Cooking ProceduresBest Cooking Areas on Miraclean Griddle Product TempCleaning the Miraclean Griddle Cleaning Control PanelCare of the Miraclean Surface Warranty Repairs Preventive MaintenanceAvoid Service Checklist Conditioning Miraclean Griddle PlateParts List DescriptionDescription Part Number Service Diagnosis Thermostat Removal and Replacement GAS Valve Regulator AdjustmentGAS Valve Removal and Replacement ON/OFF Switch Removal and ReplacementBurner Coil Check Thermostat Bulb Placement DetailThermopile Output Check Thermostat Resistance CheckAutomatic Pilot Dropout Check GAS Griddle Wiring Diagram Warranty Service Information

Miraclean specifications

Keating of Chicago Miraclean is a state-of-the-art commercial dishwasher designed for high-performance cleaning in the food service industry. Its innovative engineering and advanced technology make it an essential piece of equipment for restaurants, cafeterias, and catering services, providing a reliable solution for maintaining hygiene and efficiency.

One of the main features of the Miraclean is its unique wash system, which utilizes a combination of high-pressure spray jets and a powerful wash pump. This design ensures that every dish, glass, and utensil is thoroughly cleaned from all angles, removing stubborn food residues and sanitizing surfaces effectively. The dishwasher also boasts a rapid wash cycle, allowing users to process large volumes of items in a short amount of time, thus maximizing productivity during peak hours.

The Miraclean incorporates advanced temperature control technology, which ensures that water reaches the optimal temperature for both washing and sanitizing. This feature is critical in meeting health and safety standards, offering peace of mind to operators. Additionally, the machine includes an automatic rinse-aid dispensing system, which ensures that the rinse process is consistent and effective, preventing spots and streaks on glassware and ensuring a spotless finish.

Energy efficiency is another hallmark of Keating's Miraclean. With a focus on sustainability, the unit is designed to minimize water and energy consumption without compromising on performance. This efficiency not only reduces operating costs but also aligns with eco-friendly practices, making it a responsible choice for businesses looking to lower their environmental impact.

The Miraclean's user-friendly design includes an intuitive digital control panel, allowing operators to easily select wash cycles, monitor performance, and make adjustments as needed. The unit is built with durable materials, ensuring long-lasting performance and reducing the need for frequent repairs.

In summary, Keating of Chicago Miraclean is a highly efficient, reliable, and user-friendly commercial dishwasher equipped with innovative technology and features that address the demanding needs of the foodservice industry. With its powerful cleaning capabilities and commitment to sustainability, the Miraclean is a smart investment for any establishment looking to improve their dishwashing operations while maintaining high standards of cleanliness and efficiency.