Keating Of Chicago Miraclean GAS Connections and Pipe Size, Restraining Devices, Leveling

Page 4

GAS CONNECTIONS AND PIPE SIZE

The Miraclean® Griddle requires a standard gas pipe size of 3/4 inch (19mm) I.D. connection. The size of the gas supply pipe is very important if the pipe is too small you will have low gas pressure at the Miraclean® Griddle manifold. Low gas pressure will cause slow recovery and/or delayed ignition. If you have a question about gas pipe size call your local gas company.

Before connecting new pipe to the Miraclean® Griddle the pipe must be blown out to remove all foreign

FLEXIBLE GAS CONNECTORS AND QUICK

DISCONNECT DEVICES

For an appliance equipped with casters:

The installation shall be made with a connector that complies with the Standard for Connectors for Movable Gas Appliances, ANSI Z21.69 or the Standard for Connectors for Moveable Gas Appliances, CAN/CGA- 1.16, and a quick disconnect device that complies with the Standard for Quick-Disconnect Devices for Use With Gas Fuel, ANSI Z21.41 or the Standard for Quick Disconnect devices for Use with Gas Fuel, CAN1-6.9.

RESTRAINING DEVICES

particles. These particles in the controls or burners may cause improper or dangerous operating conditions.

Pipe joint compounds that are used on threaded joints of appliance piping shall be resistant to the action of liquified petroleum gases. When using pipe joint compound do not apply to the first two threads. Use only very small amount and only on male threads. This will prevent clogging of burner orifices and the gas

WARNING

Restraining devices

required.

Adequate means must be provided to limit the movement of the appliance without depending on the connector and the quick-disconnect device or its associated piping to limit the appliance movement.

Griddle installation on stands with caster, casters and jam nuts must be completely tightened.

valve. Never use compound on female threads as it might be pushed into the gas valve.

Have your installer check for gas leaks using a soap and water solution before operating. DO NOT USE AN OPEN FLAME TO CHECK FOR GAS LEAKS.

1)The Miraclean® Griddle and its individual shut off valves must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess of 1/2 psi (3.45kPa) (13.84 in WC) High pressure can damage the gas

valve causing a hazardous condition. WARNING 2.) The appliance must be isolated from the gas supply piping system by closing its individual manual shutoff valve during any pressure testing of

The restraint means must be attached to the rear of the Miraclean® Griddle within 2" of the center line and approximately 1-5/8" from the bottom of the cabinet back to allow the restraining bolt to be anchored to the cabinet back between the cabinet bottom and inner liner to ensure positive support to restrain Miraclean® Griddle movement and not depend on the flexible gas connector, quick-disconnect or piping to limit the Miraclean® Griddle movement.

If disconnection of the restraint is necessary, it must be reconnected when the Miraclean® Griddle is returned to its originally installed position.

LEVELING

Do not use open flame

the gas supply piping system at test pressures equal to or less than 1/2 psi (3.45 kPa).

to check for leaks. The required gas pressure for proper operation of each Miraclean® Griddle is 4" water column for natural gas and 10" water

column for propane gas at the manifold.

If more than one gas unit is on the same supply line, you may require a larger line. Consult your local gas company to assure adequate volume and pressure. Refer to serial plate for proper gas requirement for your particular model.

The Miraclean® Griddle will operate at its highest efficiency when properly leveled. Place a level on the Miraclean® Griddle plate from side to side. For griddles on legs, the bottom foot of the leg is adjustable. Turn counterclockwise to decrease height, or clockwise to increase height until level. For griddles on stands with casters, the casters are adjustable by loosening the jam nut. When the desired level is reached, tighten the jam nut. Adjustments of more than 3/4" are not recommended on any caster. The same procedure should be followed to level the Miraclean® Griddle from front to back.

2

Image 4
Contents Miraclean GAS Griddle For Your Safety Installation Instructions IntroductionIf Equipment Arrives Damaged First StepsFlexible GAS Connectors and Quick Disconnect Devices GAS Connections and Pipe SizeRestraining Devices LevelingPlacing Miraclean Griddle in Operation Cooking with Your Miraclean Griddle Lighting Instructions Miraclean GriddleCooking Procedures Best Cooking Areas on Miraclean GriddleProduct Temp Cooking InstructionsCleaning Control Panel Cleaning the Miraclean GriddleCare of the Miraclean Surface Preventive Maintenance Avoid Service ChecklistConditioning Miraclean Griddle Plate Warranty RepairsDescription Parts ListDescription Part Number Service Diagnosis GAS Valve Regulator Adjustment GAS Valve Removal and ReplacementON/OFF Switch Removal and Replacement Thermostat Removal and ReplacementThermostat Bulb Placement Detail Burner Coil CheckThermostat Resistance Check Thermopile Output CheckAutomatic Pilot Dropout Check GAS Griddle Wiring Diagram Warranty Service Information

Miraclean specifications

Keating of Chicago Miraclean is a state-of-the-art commercial dishwasher designed for high-performance cleaning in the food service industry. Its innovative engineering and advanced technology make it an essential piece of equipment for restaurants, cafeterias, and catering services, providing a reliable solution for maintaining hygiene and efficiency.

One of the main features of the Miraclean is its unique wash system, which utilizes a combination of high-pressure spray jets and a powerful wash pump. This design ensures that every dish, glass, and utensil is thoroughly cleaned from all angles, removing stubborn food residues and sanitizing surfaces effectively. The dishwasher also boasts a rapid wash cycle, allowing users to process large volumes of items in a short amount of time, thus maximizing productivity during peak hours.

The Miraclean incorporates advanced temperature control technology, which ensures that water reaches the optimal temperature for both washing and sanitizing. This feature is critical in meeting health and safety standards, offering peace of mind to operators. Additionally, the machine includes an automatic rinse-aid dispensing system, which ensures that the rinse process is consistent and effective, preventing spots and streaks on glassware and ensuring a spotless finish.

Energy efficiency is another hallmark of Keating's Miraclean. With a focus on sustainability, the unit is designed to minimize water and energy consumption without compromising on performance. This efficiency not only reduces operating costs but also aligns with eco-friendly practices, making it a responsible choice for businesses looking to lower their environmental impact.

The Miraclean's user-friendly design includes an intuitive digital control panel, allowing operators to easily select wash cycles, monitor performance, and make adjustments as needed. The unit is built with durable materials, ensuring long-lasting performance and reducing the need for frequent repairs.

In summary, Keating of Chicago Miraclean is a highly efficient, reliable, and user-friendly commercial dishwasher equipped with innovative technology and features that address the demanding needs of the foodservice industry. With its powerful cleaning capabilities and commitment to sustainability, the Miraclean is a smart investment for any establishment looking to improve their dishwashing operations while maintaining high standards of cleanliness and efficiency.