Miele DA250-4 installation instructions Grease filter timer, Checking the grease filter timer

Page 14

Operation

Grease filter timer

A timer monitors the hours of fan operation. The indicator for the grease filter will light after 30 hours of operation or the preselected time. The grease filter must then be cleaned. See "Cleaning and care / Grease Filter".

After the grease filter has been cleaned and put back in place, the grease filter timer must be reset.

^To do this, press the grease filter button for about 3 seconds while the fan is running.

The indicator will go out.

Checking the grease filter timer

To check the percentage of time already used:

^Press the On/Off button to turn the fan on.

^Press the grease filter button. The indicator lights.

The number of flashing "–/+" indicators show the percentage of programmed hours that have been used.

1 indicator = 25 %

2 indicators = 50 %

3 indicators = 75 %

4 indicators = 100 %

This information will remain stored in memory in the event of a power failure.

14

Image 14
Contents Operating and Installation Instructions Ventilation System Contents Important Safety Instructions Use Evacuate and Call the Fire Department Only ifInstallation To reduce the risk of fire only use metal ductworkFunctional description Guide to the hood Grease filter button On/Off button Fan power level buttonsDelayed Shut Down Automatically switching back the intensive power level Selecting the power levelIntensive setting OperationFan performance Automatic Safety Shut Off Turning off the fanTurning the lighting on/off Dimming the lightingGrease filter timer Checking the grease filter timerReprogramming the grease filter timer Stainless steel Cleaning and careCleaning the casing Stainless steel colored controlsRemoving the grease filter Cleaning the grease filter Changing the light bulb MieleCare After Sales ServiceRepairs Installation Instructions Page Disposal of an old appliance Caring for the environmentDisposal of packing material Structural support Electrical data This Appliance Must be GroundedAppliance dimensions Installation Installation instructions Installation accessoriesAir extraction Condensate trap Page Alteration rights reserved