Miele DA250-4 installation instructions Condensate trap

Page 30

Air extraction

If the exhaust is ducted into an inactive flue, the air must be expelled parallel to the flow direction of the flue.

Never connect an exhaust hood to an active chimney, dryer vent, flue, or room venting ductwork. Seek professional advice before connecting an exhaust hood vent to an existing, inactive chimney or vent flue.

Important

If the ductwork runs through rooms, ceilings, garages, etc. where temperature variations exist, it may need to be insulated to reduce condensation.

Condensate trap

optional accessory

In some cases, a condensate trap may be required to collect and evaporate any condensation which may develop. This optional accessory is available for ducts 5" (125 mm) and 5 7/8" (150 mm) in diameter.

^When installing a condensate trap, ensure that it is positioned vertically and if possible directly above the exhaust outlet.

30

Image 30
Contents Operating and Installation Instructions Ventilation System Contents Important Safety Instructions Use Evacuate and Call the Fire Department Only ifInstallation To reduce the risk of fire only use metal ductworkFunctional description Guide to the hood On/Off button Fan power level buttons Delayed Shut DownGrease filter button Automatically switching back the intensive power level Selecting the power levelIntensive setting OperationFan performance Automatic Safety Shut Off Turning off the fanTurning the lighting on/off Dimming the lightingGrease filter timer Checking the grease filter timerReprogramming the grease filter timer Stainless steel Cleaning and careCleaning the casing Stainless steel colored controlsRemoving the grease filter Cleaning the grease filter Changing the light bulb After Sales Service RepairsMieleCare Installation Instructions Page Caring for the environment Disposal of packing materialDisposal of an old appliance Structural support Electrical data This Appliance Must be GroundedAppliance dimensions Installation Installation instructions Installation accessoriesAir extraction Condensate trap Page Alteration rights reserved