Miele DA250-4 installation instructions Functional description

Page 7

Functional description

The ventilation hood works by air extraction. The air is drawn in and cleaned by the grease filter and directed outside.

The hood comes equipped with a non-return flap. This flap automatically closes when the hood is turned off so that no exchange of outside air and room air can occur. When the hood is turned on, the air pressure of the exhaust fan automatically opens the flap blowing the inside air and cooking odors outside.

7

Image 7
Contents Operating and Installation Instructions Ventilation System Contents Important Safety Instructions Use Only if Evacuate and Call the Fire DepartmentTo reduce the risk of fire only use metal ductwork InstallationFunctional description Guide to the hood Delayed Shut Down On/Off button Fan power level buttonsGrease filter button Operation Selecting the power levelIntensive setting Automatically switching back the intensive power levelFan performance Turning off the fan Automatic Safety Shut OffDimming the lighting Turning the lighting on/offChecking the grease filter timer Grease filter timerReprogramming the grease filter timer Stainless steel colored controls Cleaning and careCleaning the casing Stainless steelRemoving the grease filter Cleaning the grease filter Changing the light bulb Repairs After Sales ServiceMieleCare Installation Instructions Page Disposal of packing material Caring for the environmentDisposal of an old appliance Structural support This Appliance Must be Grounded Electrical dataAppliance dimensions Installation Installation accessories Installation instructionsAir extraction Condensate trap Page Alteration rights reserved