Connection for air extraction

Important: To avoid the danger of toxic fumes, please observe the Warning and Safety instructions. This is especially crucial when using the rangehood at the same time as another heating appliance which relies on air from the same room. The rangehood should be installed according to local and national building regulations. Seek approval from the building inspector where necessary.

Only use smooth pipes or flexible hoses made from non-flammable materials for the extraction ducting.

When using an external motor, make sure that the exhaust ducting is sufficiently rigid. The external motor can cause an underpressure which can result in the exhaust ducting distorting.

To achieve the greatest possible air extraction with the lowest noise level, please note the following:

To ensure efficient air extraction, the diameter of the exhaust ducting should not be less than 150 mm.

If flat ducting is being used, the cross-sectional area must not be smaller than the cross-sectional area of the exhaust connection.

If exhaust ducting with a diameter of less than 150 mm, or if flat ducting is used, the noise level of the rangehood will increase and extraction will be less efficient.

All ducting, pipework and fittings must be of non-flammable materials.

The exhaust ducting should be as short and straight as possible.

Only use wide radius bends.

The exhaust ducting should not be kinked or compressed.

Ensure that all connections are strong and airtight.

31

Image 31 Contents
En AU, NZ Contents Disposal of the packing material Caring for the environmentDisposal of your old appliance or machine Correct application Safety with childrenTechnical safety Page Page Correct use Accessories Correct installationGuide to the appliance Touch control for the charcoal filter Cooktop lighting Charcoal filterTouch control for the cooktop lighting Touch control for grease filtersAn external motor Description of the functionsAir extraction Air recirculationConctivity MielehomeIntensive setting To switch the fan onTo select a power level Automatic switch-off of the Intensive settingRun-on option To switch the fan offTo dim the cooktop lighting To switch the cooktop lighting onTo switch the cooktop lighting off Safety cut-outAltering the operating hours counter for the grease filters Reading the operating hours counter for the grease filtersOperation Reading the operating hours counter for the charcoal filter General notes Cleaning and careHousing Important for appliances with stainless steel housingControls Grease filtersCleaning the grease filters in the dishwasher Cleaning the grease filters by handFitting and replacing the charcoal filter Changing a halogen lamp Warranty After sales serviceConnection for air extraction Appliance dimensionsSafety distance S Assembly parts InstallationNon-return flap Conversion kit for recirculation modeLever for dismantling the tower Installation instructions Protective sheetsProtective foil Installation instructionsDismantling Connection for air extraction Condensate trap Air extraction with external motor Recirculation modeSilencer With air extractionElectrical connection Potential free connection Connection to a light switchInstallation Operation with control module DSMFan performance Technical dataPage Page Page Alteration rights reserved Nr 201 520