Miele DA 8-2 manual Calculation of exhaust ducting

Page 18

Exhaust connections

Calculation of exhaust ducting

A pipe diameter of 5" should ensure trouble-free extraction up to a total pipe length of 5.4. meters (17 1/2 ft).

Determine the total pipe length as fol- lows:

Measure the total length of ducting needed.

Add the length of additional ducting to this figure according to the num- ber and type of bends (see table below).

Example

Wall vent (1)

1.1 m

43’’

Flexible

 

 

90° bend (2)

0.3 m

12’’

Note

If the exhaust ducting will run through rooms, ceiling space etc. where there may be variations in temperature the problem of sweating or condensation will have to be addressed.

The exhaust ducting may need to be in- sulated.

Flexible pipe (3)

1.0 m

39’’

Flexible

 

 

45° bend (4)

0.2 m

8’’

 

 

 

Total pipe length

2.6 m

81/2’’

With a total pipe length of 81/2 ft. (102’’) the exhaust is within the effec- tive range.

Air flow rates:

- Setting 1 240 m3/h (145 CFM)

- Setting 2 465 m3/h (275 CFM)

Type of bend

Angle

Radius of

Radius of

Effective

Effective

 

of bend

bend

bend

pipe length

pipe length

 

 

(in mm)

(in inches)

(in meters)

(in inches)

 

 

 

 

 

 

Flexible pipe

45°

120

4 3/4

0.2

8’’

 

90°

120

4 3/4

0.3

12’’

 

 

 

 

 

 

Wall vent

 

 

 

1.0

39’’

18

Image 18
Contents DA 8-2 Extractor Description of the appliance Data plate Help protect our environment Disposal of packagingDisposal of your old machine Contents Page For the installer and electrician Disposal of an old appliance Operation After cookingCleaning and care Grease filterControl panel / Control knob After Sales Service Electrical connection Electrical connection CDNElectrical connection USA Appliance dimensions 14 3/16 19 5/16Installation instructions Extractor e.g. DACombiset Exhaust connection Exhaust connections Vent connection variations10 1/4 Calculation of exhaust ducting Page Alteration rights reserved / 22 CDN, USA