Cleaning and care
Before cleaning the extractor dis- connect it from the main electrical supply (pull out the plug or trip the circuit breaker).
Grease filter
A
The grease filter can be cleaned in a dishwasher or by hand.
The grease filter should be cleaned regularly to ensure trouble free oper- ation of the extractor fan.
An
To remove the grease filter the venti- lation grill (1) must be removed.
Carefully withdraw the grease filter
(2).
Make sure that no particles from the grease filter fall into the interior of the appliance. If this does happen, the Service Department will have to be called to clean the appliance, as the fan casing will need to be dis- mantled.
Loosen both screws on the grease fil- ter and remove the drip tray.
Clean the grease filter, the ventilation grill and the drip tray.
By hand: in a solution of hot water and detergent using a nylon brush, or In a dishwasher: the grease filter, the ventilation grill and the drip tray should be placed in the bottom bas- ket. Ensure that the spray arm is not obstructed.
When clean and dry, replace the drip tray on the grease filter and
Replace the ventilation grill.
Control panel / Control knob
The control panel and control knob should be cleaned in a solution of hot water and detergent and dried using a soft cloth.
Do not use abrasive cleaning agents as these will scratch the sur- face material.
10