Miele 09 968 280 installation instructions Condensate trap, Reducing Collar

Page 31

Exhaust duct

Condensate trap

In addition to insulating the exhaust duct, we recommend installing a condensate trap to collect and evaporate any condensate which might accumulate.

Condensate traps are available for exhaust ducts with a diameter of 5" (125 mm) or 6" (150 mm).

When installing a condensate trap, make sure that it is positioned vertically and, if possible, directly above the hood outlet duct collar. The arrow on the housing indicates the direction of airflow.

Reducing Collar

(optional accessory)

If you would like to reduce the environmental impact of your ventilation system by limiting the CFM output the Reducing Collar can be installed. It reduces the air flow to less than 400 CFM. Check local building codes for max. CFM requirements.

Push the Reducing Collar on the exhaust port of the fan.

Push the exhaust hose over it.

Fix both with a hose clamp.

31

Image 31
Contents Operating and Installation Instructions Ventilation Hood Contents Important Safety Instructions Children Important Safety Instructions Proper use Important Safety Instructions Important Safety Instructions Proper installation  Warning to Reduce the Risk of Fire USE only Metal Ductwork Cleaning and care Disposal of the packing material Caring for the environmentDisposal of your old appliance Non-return flap Vented modeRecirculation mode Description of functionsGuide to the appliance Guide to the appliance Turning on the fan Selecting the power levelAutomatically switching back from the intensive level is OperationTurning off the fan Automatic safety shut-downTurning cooktop lighting On/Off General Cleaning and careStainless steel housing Special instructions for RAL color finish housingSpecial instructions for glass surfaces Cleaning intervalsGrease filter Special instructions for control buttonsCleaning the grease filter in a dishwasher After cleaningCleaning the grease filter by hand Unsuitable cleaning agentsDisposing of the OdorFree Charcoal Filter Installing/replacing the OdorFree Charcoal FilterWhen to change the OdorFree Charcoal Filter OdorFree Charcoal FilterChanging a light bulb Disassembly InstallationBefore installation Installation InstructionsInstallation parts Protective spacers Recirculation kit for recirculation modeInstallation sheet ReducerAppliance dimensions Installation Distance between cooktop and ventilation hood S Drilling diagram for wall mounting Installation recommendationsExhaust duct Reducing Collar Condensate trapGrounding Instructions Electrical connectionWarranty Service and warrantyLocation of the data plate Technical data Canada DA 5966 W DA 5986 W DA 5996 W En-US Nr 968 280