Miele DA 3190, DA 3160 Description of the functions, Air extraction, Air recirculation

Page 12

Description of the functions

The cooker hood works with

. . . air extraction:

The air is drawn in, cleaned by the grease filter and then directed outside.

If the on-site ventilation system does not have a non-return flap, then the non-return flap supplied with the appliance must be fitted in the exhaust socket in the motor unit.

Having a non-return flap fitted in the ducting ensures that air, once ducted to the outside, cannot get back into the room again.

The flap is closed when the cooker hood is switched off.

When the cooker hood is switched on, the non-return flap opens for the cooking vapours to be blown directly outside.

. . . air recirculation:

(air recirculation conversion kit required)

The air is drawn in and cleaned first by the grease filter and then by a charcoal filter. The cleaned air is then recirculated back into the kitchen.

Charcoal filters are available to order through your Dealer / Chartered Agent or the Miele Spare Parts Department or via the internet at www.miele-shop.com. (See back cover for contact details and "Technical Data" for model number).

Before using the cooker hood in recirculation mode, ensure that the charcoal filter is in place; see "Cleaning and care".

12

Image 12
Contents Operating and installation instructions Cooker hood Contents Caring for the environment Disposal of the packing materialDisposal of your old appliance Safety with children Technical safetyCorrect application Page Page Page Correct installation Correct use Accessories Guide to the appliance Drop-down lightshield to conceal control panel Description of the functions Air extractionAir recirculation Operation Automatic switch-off of the Intensive setting Safety cut-outCleaning and care HousingImportant for appliances with stainless steel housing General notesGrease filter ControlsImportant for DFB aluminium lightshields Cleaning the grease filters by hand Cleaning the grease filters in the dishwasherFitting and replacing the charcoal filter Changing a halogen lamp Appliance dimensions Safety distance between hob and cooker hood Installation Installation accessoriesConversion kit for recirculation mode DML 300 installation kit optional accessoryHose clips Non-return flapInstallation Positioning the appliance in the wall housing unit Installation Installation Secure the spacer strip to the back Weight of a lightshield matching existing furniture Attaching the lightshieldAligning the deflector plate Replacing the grease filter Set up for extraction mode Set up for recirculation mode Electrical connectionConnection for air extraction Condensate trap Electrical connection Connection to a window contact switch Operation with DSM 400 control modulePotential free connection Connection to a light switch InstallationAfter sales service Technical data Page Alteration rights reserved Nr 794 960