OPERATION

WARNING: THE STOCKPOT RANGE AND ITS PARTS ARE HOT. BE CAREFUL WHEN OPERATING, CLEANING OR SERVICING THE STOCKPOT RANGE.

CONTROLS

The burner is in two sections, controlled by two heavy duty infinite control valves. The center “Star” section (Fig. 2) is on separate burner with an input of 55,000 BTU/hr. It is controlled by the right burner valve knob. The outer circle of the burner (Fig. 2) is the other separate 55,000 BTU/hr input burner, controlled by the left burner valve knob.

These two separate burners provide heat flexibility. With one burner off and the second burner set low, up to both burners full on, you can move from low simmer on up to 110,000 BTU/hr input.

PILOT VALVE

SCREW

INNER

BURNER

OUTER

BURNER

Fig. 1

Fig 2.

LIGHTING INSTRUCTIONS

1.Turn all burner valves to OFF position and wait 5 minutes.

2.Turn gas shutoff valve ON.

3.Light standing pilot with a lit taper. Adjust pilot to ¼” high flame, if necessary, by turning pilot valve adjusting screw (see Fig. 1) counterclockwise to increase or clockwise to decrease flame.

4.Turn burner valve to ON position.

5.If pilot does not light, turn main gas supply OFF and repeat steps 1 through 4.

TO COMPLETELY SHUTDOWN THE BURNERS AND PILOT LIGHTS

For complete shutdown: Turn the main gas supply valve OFF.

- 6 -

Image 6
Contents Stockpot Range Retain this Manual for Future USEImportant for Your Safety For Your SafetyUnpacking INSTALLATION, Operation and Care Stockpot Range GeneralInstallation LocationInstallation Codes and Standards GAS Pressure Regulator InstallationLeveling Ventilation HoodGAS Connection Lighting Instructions OperationControls To Completely Shutdown the Burners and Pilot LightsCleaning MaintenanceTroubleshooting Service