GRID

The removable sliding grid, with usable area of 13" x 25" (330 x 635), can be mounted in 3 separate positions, allowing loading clearance from 11/4" to 5" (32 to 127).

OPERATING THE BROILER

To place 220/380 and 208/240 volt broilers into operation, turn the infinite switch knob to the desired setting.

To place 480 volt broilers into operation, turn the 3-heat, 4-position switch knob to the desired setting.

Wait 5 minutes for the broiler to preheat, then follow normal cooking procedures.

GRID ADJUSTMENT

Position the grid farther away from the burners for thick meats and for melting cheese or butter to avoid drying the product. Position the grid closer to the burners for bacon, toast and quick heating. Watch carefully to avoid burning.

LOADING AND UNLOADING

Place the grid in the desired position. Pull grid out far enough to load product. Push grid back in place for cooking. Pull grid out for unloading.

CARE AND CLEANING

Follow the recommended procedure for general care and cleaning provided with the range.

POWER OUTAGE

If a power outage occurs, the broiler will automatically shut down. When power is restored, the broiler will automatically start heating.

If the broiler is left unattended during the power outage, turn either the infinite switch knob (220/380

&208/240 volt) or the 3-heat, 4-position switch knob (480 volt) to the OFF position. When power is restored, turn control knob back to ON position. The broiler will be preheated in 5 minutes and normal cooking operation can then be resumed.

— 7 —

Image 7
Contents Installation VB73 Salamander Broiler Mounted Over VR2 Range Table of Contents Installation Codes and Standards InstallationUnpacking Location AssemblyElectrical Connections Controls Figs OperationGrease PAN Fig Grid Grid AdjustmentCare and Cleaning Power OutageProblem Possible Cause MaintenanceTroubleshooting Service and Parts InformationPossibles Causes Meèprobl Rechange DE Cesèpi ET ENTRETIEN’L DE ServicePannageéd EntretienGrille LA DE Positionnement Courant DE PanneNettoyage Chargementéd ET ChargementFonctionnement Lectriqueé Raccordement ESB36 et VB73R VB73, grilloirs-SalamandresESB36 grilloir-Salamandre VB73R et VB73 grilloirs-SalamandresBallageéd Normes ET INSTALLATION’D CodesResèmati DES Table VR2 Reècuisini UNE SUR Eéinstall VB73 GRILLOIR-SALAMANDRE Demploi Mode