Vulcan-Hart VPX5 126588, VPX3 126586 manual Timer, Standby Thermostat, High Limit Thermostat

Page 5

VPX SERIES STEAMERS - REMOVAL AND REPLACEMENT OF PARTS

4.Reverse procedure to install replacement component and check steamer for proper operation.

NOTE: If replacing temperature control, see

"TEMPERATURE CONTROL CALIBRATION - ADJUSTMENT FOR ELEVATION" in "SERVICE PROCEDURES AND ADJUSTMENTS".

TIMER

WARNING: DISCONNECT THE ELECTRICAL POWER TO THE MACHINE AT THE MAIN CIRCUIT BOX. PLACE A TAG ON THE CIRCUIT BOX INDICATING THE CIRCUIT IS BEING SERVICED.

1.Remove right side panel as outlined under

"COVERS AND PANELS".

2.Disconnect lead wires to timer.

3.Loosen two set screws on dial and pull timer knob from shaft.

4.Remove nut from timer shaft and remove timer.

5.Reverse procedure to install.

STANDBY THERMOSTAT

WARNING: DISCONNECT THE ELECTRICAL POWER TO THE MACHINE AT THE MAIN CIRCUIT BOX. PLACE A TAG ON THE CIRCUIT BOX INDICATING THE CIRCUIT IS BEING SERVICED.

1.Remove right side panel as outlined under

"COVERS AND PANELS".

2.Pull insulation back to expose standby thermostat and disconnect lead wires.

3.Grasp thermostat body and push up to slide holding tabs out from mounting bracket.

4.Apply a small amount of "thermal transfer compound" to the mating surface (disk side) of the replacement thermostat.

A.Spread the compound completely and evenly over the surface of the thermostat.

5.Reverse procedure from step 3 to install and check steamer for proper operation.

HIGH LIMIT THERMOSTAT

WARNING: DISCONNECT THE ELECTRICAL POWER TO THE MACHINE AT THE MAIN CIRCUIT BOX. PLACE A TAG ON THE CIRCUIT BOX INDICATING THE CIRCUIT IS BEING SERVICED.

1.Remove right side panel as outlined under

"COVERS AND PANELS".

2.Pull insulation back to expose high limit thermostat and disconnect lead wires.

3.Remove thermostat from heating element assembly.

Page 5 of 20

 

F25111 (March 2002)

 

Image 5
Contents Model ML VPX Series Electric Countertop SteamersTable of Contents Specifications INSTALLATION, Operation Cleaning IntroductionGeneral ToolsComponent Panel Components Removal and Replacement of PartsCovers and Panels High Limit Thermostat TimerStandby Thermostat Heating Element Assembly Temperature ProbeVPX Series Steamers Removal and Replacement of Parts Manual Drain Valve Removal DoorHandle GasketLatch Assembly Service Procedures and AdjustmentsDoor Latch Adjustment To adjust Door Sealing AdjustmentHeating Element Test See table below for proper valuesKW PER Amps PER Ohms PER Voltage Element Temperature Control CalibrationComponent Location Electrical OperationComponent Function Sequence of Operation Timed Cooking ModeContinuous Cooking Mode VPX Series Steamer Electrical Operation 208-240V Wiring Diagrams480V Symptom Possible Causes TroubleshootingVPX3 & VPX5 Condensed Spare Parts List

VPX5 126588, VPX3 126586 specifications

The Vulcan-Hart VPX3 126586 and VPX5 126588 are cutting-edge commercial cooking appliances designed to enhance efficiency and performance in commercial kitchens. Both models embody the quality and reliability that Vulcan-Hart is known for, incorporating advanced technologies to meet the demands of busy restaurants, catering services, and food preparation operations.

One of the key features of the VPX3 is its powerful cooking capabilities, powered by a robust heating system that ensures rapid heat-up times and consistent cooking temperatures. It has a spacious cooking surface, accommodating multiple pots and pans simultaneously, making it an ideal solution for high-volume cooking. The VPX3 also offers precise temperature control, allowing chefs to achieve the perfect cooking results every time.

The VPX5 takes functionality a step further with its enhanced features. It includes multiple burners, which allow for versatile cooking options, catering to various menu items simultaneously. The VPX5 is designed to provide even heat distribution, reducing cooking times while maintaining food quality. The model also boasts advanced safety features, including safety shut-off valves and easy-to-use controls, ensuring a safe working environment.

Both models are equipped with user-friendly electronic controls and a digital display, making them intuitive to operate. The robust construction using high-quality stainless steel increases durability and makes for easy cleaning, a critical aspect in busy kitchen environments. The grease filter and removable drip tray ensure that excess oils and food debris do not interrupt the cooking process, contributing to overall hygiene.

In addition to their cooking prowess, both the VPX3 and VPX5 are energy-efficient, adhering to modern energy standards and helping to lower actual operating costs. Their compact design allows them to fit into various kitchen layouts without taking up unnecessary space while still providing exceptional performance.

In conclusion, the Vulcan-Hart VPX3 126586 and VPX5 126588 exemplify superior engineering and design, making them a valuable addition to any commercial kitchen. With their powerful cooking capabilities, advanced features, and emphasis on safety and efficiency, these models are perfect for chefs looking to elevate their culinary operations.