PREPARATION
1.Use the dimensional drawings (Refer to FIGURES 1 - 3) to lay
out the range hood's mounting holes, vin'ing access and ductwork
by marking the cabinet bottom and drywall where applicable.
2.Make cutouts for wiring and ductwork.
3.If the hood is to be ducted,install the ductwork so that is flush to
the range hood's mounting surface.
Refer to FIGURE 1 if the range hood is to be installed with a
horizontal discharge.
Refer to FIGURE 2 and FIGURE 3 if the range hood is to be installed with a vertical discharge.
4.Run
the hood location.B(mg approximately 12"of wiring through wir- ing hole in cabinet.
5.DriU four 3/32" diameter pilot holes at points where mounting holes are marked in cabinet bottom.
6.Insert four (4) mounting screws, leaving approximately ¼" of thread exposed.
7.Remove and retain the mounting screws securing the 3¼"x 10"
and 7 _ duct transitions to the hood. Install the appropriate duct
transition as described in the installation section.
I N STALLATIO N
1. Remove the necessary duct opening and wiring knockout from the range hood.
If the range hood is to be installed as a
move the wiring knockout only.
If the range hood is to be installed as a dueted unit, a baffle
plate is provided to close off the nonMucted vent. InstaB baffle plate (Refer to FIGURE 4) by sliding into place behind grille. Use locator bumps to orient in grille.
2.For 7" round discharge installation, refer to FIGURE 5. Secure
7" adapter (included) to top of hood using screws provided, in-
stall 7" round damper (Model BPg7, purchased separately).
For 3V_x | 10" vertical _ |
| installation, | refer to | FIGURE 6. Se- | |||||
cure | 3¼" | x | 10" transition | (if used) to top of hood. |
|
| ||||
For 3_i" x | 10" | horizontal | discharge | installation, | refer to | FIG- | ||||
URE | 7. | If using | the supplied | 3¼ _ 10" duct | transition, | remove | the |
damper flap from the transition to prevent possible venting inter- ference. Position transition into wall cutout. Note:The transition does not fasten to the hood.
3.Feed the wiring through the access hold and into the electrical box.
4.Align hood's keyhole mounting slots over the four (4) partially installed screws.
5.Making sure the duct positions over the hood's duct transition,
push the hood against the rear wail. Secure hood by tightening
SCreWS.
6.Using a long blade screwdriver, reach into the discharge opening and make sure the damper flap operates freely (vertical discharge only).
LOCATORS
_ | BAFFLE PLATE |
FIGURE 4
ADAPTER (Included)
FIGURE 5
SECURE TRANSITION
TWITH SCREWS (Included)
FIGURE 6
POSITION DUCT
TRANSITION iN
WALL CUTOUT
÷,°
HORIZONTAL
FIGUILE7