Sears 233.52157, 233.52153, 233.52059 Preparation, Stallatio N, For Vertical, Refer to, Remove

Page 4

PREPARATION

1.Use the dimensional drawings (Refer to FIGURES 1 - 3) to lay

out the range hood's mounting holes, vin'ing access and ductwork

by marking the cabinet bottom and drywall where applicable.

2.Make cutouts for wiring and ductwork.

3.If the hood is to be ducted,install the ductwork so that is flush to

the range hood's mounting surface.

Refer to FIGURE 1 if the range hood is to be installed with a

horizontal discharge.

Refer to FIGURE 2 and FIGURE 3 if the range hood is to be installed with a vertical discharge.

4.Run two-conductorwire (with ground) from a power source to

the hood location.B(mg approximately 12"of wiring through wir- ing hole in cabinet.

5.DriU four 3/32" diameter pilot holes at points where mounting holes are marked in cabinet bottom.

6.Insert four (4) mounting screws, leaving approximately ¼" of thread exposed.

7.Remove and retain the mounting screws securing the 3¼"x 10"

and 7 _ duct transitions to the hood. Install the appropriate duct

transition as described in the installation section.

I N STALLATIO N

1. Remove the necessary duct opening and wiring knockout from the range hood.

If the range hood is to be installed as a non-ducted unit, re-

move the wiring knockout only.

If the range hood is to be installed as a dueted unit, a baffle

plate is provided to close off the nonMucted vent. InstaB baffle plate (Refer to FIGURE 4) by sliding into place behind grille. Use locator bumps to orient in grille.

2.For 7" round discharge installation, refer to FIGURE 5. Secure

7" adapter (included) to top of hood using screws provided, in-

stall 7" round damper (Model BPg7, purchased separately).

For 3V_x

10" vertical _

 

installation,

refer to

FIGURE 6. Se-

cure

3¼"

x

10" transition

(if used) to top of hood.

 

 

For 3_i" x

10"

horizontal

discharge

installation,

refer to

FIG-

URE

7.

If using

the supplied

3¼ _ 10" duct

transition,

remove

the

damper flap from the transition to prevent possible venting inter- ference. Position transition into wall cutout. Note:The transition does not fasten to the hood.

3.Feed the wiring through the access hold and into the electrical box.

4.Align hood's keyhole mounting slots over the four (4) partially installed screws.

5.Making sure the duct positions over the hood's duct transition,

push the hood against the rear wail. Secure hood by tightening

SCreWS.

6.Using a long blade screwdriver, reach into the discharge opening and make sure the damper flap operates freely (vertical discharge only).

LOCATORS

_

BAFFLE PLATE

FIGURE 4

ADAPTER (Included)

FIGURE 5

SECURE TRANSITION

TWITH SCREWS (Included)

FIGURE 6

POSITION DUCT

TRANSITION iN

WALL CUTOUT

÷,°

HORIZONTAL

FIGUILE7

Image 4
Contents Owners MAN UAL Range HoodModel Nos Sears, Roebuck and Co., Hoffman Estates, IL 60179 U.S.APlan the Installation Important Safety InstructionsTelephone number listed in the warranty =IL L,. t-11/2 Preparation Stallatio NFor Vertical Refer toFilter Installation Replacement MaintenanceService Parts KEY NO. Part noWarranty Limited WarrantySears OWN E RS Range HanualhoodCampana DE Cocina Manual DEL DuenoModelos Nos Instrucciones DE Seguridad PlaneamientoCuidado pARA Reducir EL Riesgo DE FUEGO, Descarga Sl I.A Campana DE Cocina no SE Conecta a ConductosSu,,R,O, l i-lo Descarga Horizontal Traves DE LA ParedPreparacion InstalacionInstalacion Y Reemplazo DE Lampara Instalacion Y Reemplazo DE FiltroHantenihiento EX,UESTOPiezas DE Servicio Codigo NO. PiezaGarantia Garantia LimitadaModelosNos Manual DEL DueiioLiame de 7 am a 7 pro, 7 alias a la semana