Sears 32O2O, 32O21, 32025 warranty Preparation, Electrical Connections, GAS Connections

Page 6

PREPARATION

Adequate counterspace must be provided for the unit. The area should be easy to reach and be lighted with natural light during the day.

See t he first page for cutout dimensions. Mark the cutout on t he counter. Use a hand or saber saw to make t he cut.

ELECTRICAL CONNECTIONS

Call your Electric Company and ask which codes apply

In your area. If there are no codes, you must follow the

NATIONAL ELECTRICAL CODES, ANSI/NFPA NO. 70- Latest Edition. You can get a copy by wrlUng:

National Fire Protection Association

Batterymarch Park

Quincy, MA 02269

The counter unit cord has a three prong plug and must be plugged Into a properly grounded three hole outlet. The outlet must be In a standard 120 Volt, 60 Hertz AC household circuit.

Improper grounding can spark Ignition on models so equipped.

Do not under any circumstances cut or remove the grounding prong from the counter unit cord. Failure

to provide proper polarization may cause shock and tire hazard.

If you do not have a grounded three hole outlet, have an electrician change your old outlet or Install a new one.

TO temporarily use a properly polarized and grounded two hole outlet until a grounded three hole outlet can be Installed, a grounding adapter plug may be used. Have an electrician test the outlet to be sure It meets require- ments.

PLUG WITH GROUND PRONG

POLARIZED RECEPTACLE

PROPERLY POLARIZED AND

PROPERLYGROUNDED

GROUNDED RECEPTACLE

METAL EYELET

 

 

GROUND

 

RECEPTACLE

 

PLATE

 

MOUN_NG

 

SCREW

Fig. 1

Fig. 2

PREFERRED METHOD

TEMPORARY METHOD

GAS CONNECTIONS

Call your gas supplier and ask which codes apply In your area. If there are no codes, you must follow the NA-

TIONAL FUEL GAS CODE, ANSIiZ223.LStest Edition. You can get a copy by writing:

American Gas Association

1515 Wilson Boulevard

Arlington (Rosslyn), VA 22209 Know where your main gas shut off valve Is.

Shut off gas supply before removing an old range. Leave It off until hookup of new counter unit Is finished.

See figures on this page for rigid and flexible pipe hookups. Some local codes do not allow the use of copper gas pipe. If flexible connectors are allowed,

a new A.G.A. certified flexible connector is rec.

omrnended. Never reuse an old connector when installing a new unit. A manual shut-off valve, for the purpose of turning on or shutting off the gas

supply to the appliance, must be installed in the

gas supply line at anaccessible location in the cabinet below the counter unit.

We recommend that you use 1/2" gas supply line.

1"FROM BACKWALL

.<_121/2,_,_

_ FROMCUTOUT

CENTER UNE

LOCATION OF GAS SUPPLY LINE

FIG.3

5

NGINS19

Image 6
Contents Sfairs What to do if YOU Smell GAS NGSAF1NGSAF09 Important Safety Instructions Important Safety NoticeLocation Tool ListAdditional Materials Minimum Clearances to be MaintainedPreparation Electrical ConnectionsGAS Connections Pressure To Check for LeaksPressure Test Information NGINS28Removing Shipping Screws Cooktop Controls Burner BowlNGCUF02 To Start Things Cooking OFFLite Cleaning Tips Part Cleaning Materials RemarksNGCCH04 GAS Valve Orifice LIFT-UP CooktopRemovable Cooktop Burners Ignite Flash Tube Burner PortsSolution Before Calling for ServiceProblem Removable KnobsPage WE Service What WE Sell Full 90-DAY Warranty on Mechanical Adjustments