GAS CONNECTIONS (continued)
A pressure regulator IS supplied and must be Installed In the gas supply line underthe unit. Install the regulator
in the gas supply line between the shut off valve
and the unit connection (see Fig ure 5). The top of the regulator should face toward the cabinet front and be easily accessible through the cabinet doors.
NOTE: The pressure regulator Is set for natural gas. To use L.P. gas, the regulator must be converted.
To convert for L.P. gas, unscrew the cap and remove the spring retainer (see Figure 4). Turn the spring retainer over and put It back Into the regulator. L. P. should be visible on the spring retainer. Replace the cap.
NAT. |
| m |
| L.P. |
6,,w.c |
|
| w.c. | |
|
|
|
| |
_L* I===l | L .... |
|
|
|
L_d |
|
|
| Fig. 4 |
|
|
|
| |
| PRESSURE REGULATOR |
|
| |
| ,_19 | 112" |
|
|
|
|
|
| _:'._ 45 ° |
|
|
|
| I |
|
| PRESSURE _ | _ | I |
|
| I | ||
|
|
|
|
I
f
I
I
RECOMMENDED PIPE
Use pipe wrenches to make connections. Do not put any strain on the connection line assembly.
Any openings around gas and electric outlets must be sealed at the time of Installation. When you are finished making connections, be sure that control knobs are turned to OFF before you open the main gas supply valve.
See next page for information on placing burner tops on cooktop burners.
TO CHECK FOR LEAKS:
Apply a soap solution to all gas connections. Bubbles will form where any gas Is leaking.
DO NOT use an open flame to look for leaks.
Turn off main gas supply before you try to stop a leak.
Turn main gas supply back on and recheck connections after stopping any leaks.
Be sure all leaks are stopped before lighting pilots (some models) or burner.
PRESSURE TEST INFORMATION
The maximum allowable test pressure for the regulator is 14" W.C. The minimum pressure needed to check the regulator setting is 7" W.C. for natural gas or 11 "W.C. for L.P. gas.
CAUTION: The range and its individual shut off
valve must be disconnected from the gas supply piping system during any pressure testing of the gas supply system at test pressures in excess of 1/2 psig (pounds per square inch gauge).
The range must be Isolated from the gas supply piping system by closing Its Individual shut off valve during any pressure testing of the gas supply system at test pressures equal to or less than 1/2 pslg.
6 | NGINS28 |