Vulcan-Hart 52399, VSX4, VSX5 Anchoring Steamer Without Legs, Stacking KIT, Electrical Connection

Page 3

ANCHORING STEAMER (Without Legs)

1.Place steamer in the desired location on the leveled counter top and mark four corners. Remove the steamer and drill 1/2" holes as indicated in Fig. 1.

2.Apply a bead of RTV or other equivalent sealant around the bottom perimeter edge of the steamer. If anchoring the steamer, this bottom seal is necessary to meet NSF requirements.

3.Set steamer on counter and bolt down securely with 3/8 - 16 bolts (not supplied).

STACKING KIT

2"

27 1/2"

23 1/2"

20"

Drill 1/2" holes through counter top

Mark 4 corners on counter top

Follow instructions in the stacking kit when installing stacked convection steamers.

ELECTRICAL CONNECTION

PL-50819

24"

 

Fig. 1

WARNING: ELECTRICAL AND GROUNDING CONNECTIONS MUST COMPLY WITH APPLICABLE PORTIONS OF THE NATIONAL ELECTRICAL CODE AND/OR OTHER LOCAL ELECTRICAL CODES.

WARNING: DISCONNECT ELECTRICAL POWER SUPPLY AND PLACE A TAG AT THE DISCONNECT SWITCH INDICATING THAT YOU ARE WORKING ON THE CIRCUIT.

The wiring diagram is located on the right side panel as you face the steamer.

ELECTRICAL DATA

 

 

 

 

Rated Amps

 

 

 

 

 

 

Kilowatts Per Phase

 

 

 

 

 

Fuse Size or

 

 

 

 

3 Phase

 

 

Circuit Size

90°C Copper

Total

Volts / Hz / Ph

Amps Per Line Wire

1 Phase

Circuit Breaker Size *

(Amps)

Wire Size

KW

 

 

 

 

 

Amps

(Amps)

 

L1 - L2 L2 - L3 L1 - L3

L1

L2

L3

 

 

 

 

 

 

 

 

7.5

208 / 60 / 1

 

 

 

 

 

 

36

50

50

8

 

 

 

 

 

 

 

 

 

 

 

 

7.5

240 / 60 / 1

 

 

 

 

 

 

31

45

45

8

 

 

 

 

 

 

 

 

 

 

 

 

7.5

208 / 60 / 3

2.5

2.5

2.5

21

21

21

 

30

30

10

 

 

 

 

 

 

 

 

 

 

 

 

7.5

240 / 60 / 3

2.5

2.5

2.5

18

18

18

 

25

25

14

 

 

 

 

 

 

 

 

 

 

 

 

7.5

480 / 60 / 3

2.5

2.5

2.5

9

9

9

 

15

15

16

 

 

 

 

 

 

 

 

 

 

 

 

10

208 / 60 / 1

 

 

 

 

 

 

48

70

70

8

 

 

 

 

 

 

 

 

 

 

 

 

10

240 / 60 / 1

 

 

 

 

 

 

42

60

60

8

 

 

 

 

 

 

 

 

 

 

 

 

10

208 / 60 / 3

3.3

3.3

3.3

28

28

28

 

40

40

10

 

 

 

 

 

 

 

 

 

 

 

 

10

240 / 60 / 3

3.3

3.3

3.3

24

24

24

 

35

35

10

 

 

 

 

 

 

 

 

 

 

 

 

10

480 / 60 / 3

3.3

3.3

3.3

12

12

12

 

15

15

16

 

 

 

 

 

 

 

 

 

 

 

 

15

208 / 60 / 1

 

 

 

 

 

 

72

100

100

6

 

 

 

 

 

 

 

 

 

 

 

 

15

240 / 60 / 1

 

 

 

 

 

 

63

90

90

6

 

 

 

 

 

 

 

 

 

 

 

 

15

208 / 60 / 3

5

5

5

42

42

42

 

60

60

8

 

 

 

 

 

 

 

 

 

 

 

 

15

240 / 60 / 3

5

5

5

36

36

36

 

50

50

8

 

 

 

 

 

 

 

 

 

 

 

 

15

480 / 60 / 3

5

5

5

18

18

18

 

25

25

14

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

* Dual Element Time-Delay Fuse or

 

 

 

 

 

 

 

 

 

 

 

Inverse Time Circuit Breaker

 

Circuit Size (Minimum) & Fuse / Circuit Breaker Size (Maximum) compiled in accordance with the National Electrical Code (ANSI/NFPA 70), 1993 Edition.

3

Image 3
Contents MLS 52396, 52397, 52398 Location InstallationGeneral UnpackingAnchoring Steamer Without Legs Stacking KITElectrical Connection Vent Hood Plumbing ConnectionsDrain Connections Water QualityTesting Procedure Cook OperationControls PreheatAcceptable Pan Sizes Cooking HintsPreparation Frozen Food ItemsWeekly, or more often if necessary CleaningCooking Guidelines Weight PER PANSeafood Fruit Cold Water Condenser MaintenanceService Removal of Lime Scale Deposits