Schneider Electric ACRC502, ACRC500, ACRC501 manual Network Management Card

Page 4

Control the Environment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17

How the Cool mode works

17

Setpoints

17

PID settings

18

Tune the PID loop

19

Run hours

20

Thresholds

20

Service intervals

20

Display Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21

Password & timeout . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21

Date & time . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21

Adjust display . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21

Display units . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22

Network Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23

Configure the network . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23

View Status Readings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24

Scrolling status screens . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24

Cooling unit status . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24

Cooling group status . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25

About the cooling unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25

Event Log. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26

View event log . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26

Clear event log . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26

Respond to Alarms . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27

View active alarms . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27

Clear active alarms . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27

Alarm messages and suggested actions . . . . . . . . . . . . . . . . . 27

Network Management Card

30

Quick Configuration

. . . . . . . . 30

Overview

30

TCP/IP configuration methods

30

Schneider Electric Device IP Configuration Wizard

30

.ini file utility

31

BOOTP & DHCP configuration

32

Local access to the control console

33

Remote access to the control console

33

Control console

34

ii

InRow RC Operation and Maintenance Manual

Image 4
Contents Operation and Maintenance Manual 990-3237B-001 Publication Date NovemberSchneider Electric IT Corporation Legal Disclaimer Table of Contents Network Management Card Troubleshooting Page Important Safety Information General InformationSafety Notices During Operation Hazard of Electric SHOCK, EXPLOSION, or ARC FlashStatic Electricity Hazard Checklists Initial inspection checklistCommissioning Ensure thatElectrical inspection checklist Electrical HazardMechanical inspection checklist Piping InstallationUser interface inspection checklist Start-up inspection checklistFinal inspection checklist While the equipment is operating, ensure thatDisplay Interface OperationDescription Function Using the Display Scrolling status screensMain menu screens Navigating the main menuPath Main Set Password Change Passwords Using the Path statementNavigating sub-menus Password entry Path Main Operation Limit AccessStart the cooling unit Path Main On/StandbyStop the cooling unit Standby OptionCooling unit configuration General ConfigurationPath Main Configure Unit General Path Main Configure Unit Discrete I/O Path Main Configure Unit Discrete I/O Normal StateContacts View the state of input and output contactsConfigure the cooling group Cooling Group ConfigurationPath Main Configure Group Configure Modbus Path Main Configure ModbusIdentify the cooling unit Path Main Set IdentificationHow the Cool mode works Control the EnvironmentSetpoints Path Main Set Group SetpointsPID settings Path Main Set Group PIDsTune the PID loop Loop Behavior PID Tuning CorrectionControl Method Proportional Integral Derivative Run hours Service intervalsThresholds Display Settings Password & timeoutAdjust display Date & timeDisplay units Path Main Menu Set Display UnitsConfigure the network Network ConfigurationPath Main Configure Network Cooling unit status View Status ReadingsPath Main View Unit Status Cooling group status About the cooling unitPath Main View Group Status Path Main About InRow RCEvent Log View event logClear event log Path Main View Event LogRespond to Alarms View active alarmsClear active alarms Alarm messages and suggested actionsConfigure Unit General Role Override Auto and that cooling Threshlds screenAlarm Message Severity Action Required Quick Configuration TCP/IP configuration methodsSchneider Electric Device IP Configuration Wizard Network Management CardIni file utility Bootp & Dhcp configuration Remote access to the control console Local access to the control consoleNetwork TCP/IP Boot Mode Dhcp only Advanced Dhcp Cookie Is Control console Choose Network from the Control Console menuWeb interface Access a Configured Network Management CardTelnet and SSH Simple Network Management Protocol Snmp ModbusInRow RC Operation and Maintenance Manual Recover From a Lost Password Maintenance Monthly Preventive MaintenanceCleanliness EnvironmentMechanical ElectricalSemi-Annual Preventive Maintenance FunctionalTroubleshooting Problem Possible Cause Corrective ActionProblem Possible Cause Corrective Action Page Page Worldwide Customer Support

ACRC501, ACRC502, ACRC500 specifications

Schneider Electric, a global leader in energy management and automation, has introduced its sophisticated line of edge computing solutions, namely the ACRC500, ACRC501, and ACRC502. These models are designed specifically to meet the increasing demand for efficient and reliable edge computing environments across various industries.

The ACRC500 serves as a compact and versatile solution that caters to small to medium-sized applications. It is engineered to optimize performance by utilizing advanced thermal management technologies. With a scalable architecture, the ACRC500 can easily be adapted for diverse workloads, making it ideal for facilities requiring quick deployment and efficient operation.

Meanwhile, the ACRC501 provides enhanced performance capabilities with increased processing power and memory. This model incorporates state-of-the-art technologies such as edge analytics and artificial intelligence, allowing businesses to make data-driven decisions in real time. Its robust design ensures it can withstand harsh environmental conditions, making it suitable for industrial settings. The ACRC501 also features advanced security protocols, ensuring sensitive data is safeguarded against potential cyber threats.

The ACRC502 stands out with its focus on high-density applications, offering improved data handling and processing efficiency. This model supports a wide range of connectivity options including Wi-Fi, Ethernet, and cellular networks, ensuring seamless integration into existing infrastructure. Its modular design allows for easy upgrades and scalability, making it a future-proof investment for enterprises looking to expand their edge computing capabilities.

All three models—ACRC500, ACRC501, and ACRC502—are built on Schneider Electric's EcoStruxure platform. This innovation enables real-time monitoring and analytics, facilitating proactive maintenance and reducing downtime. Furthermore, they support IoT applications, making them ideal for smart factory implementations, healthcare analytics, and energy management systems.

In addition to their high-performance features, these edge computing solutions are designed with sustainability in mind. Schneider Electric emphasizes energy efficiency and reduced carbon footprints in their development processes, aligning with global sustainability goals. The result is a suite of products that not only enhance operational efficiency but also contribute to a more sustainable future for businesses.

In conclusion, the ACRC500, ACRC501, and ACRC502 represent Schneider Electric's commitment to innovation in edge computing. With their array of features and technologies, these models are poised to meet the evolving needs of industries across the globe, driving the future of operational efficiency and sustainability.