3-9 Water Reservoir

All portable chillers shipped during the fall, winter, or spring, or those units that are shipped from stock are flushed at the factory with a water/ethylene glycol solution to prevent piping components prone to retaining water from freezing. During startup and when additional solution is required, refer to the ethylene glycol and propylene glycol curves in Figure 6 on page 26. Add a pre-mixed solution of industrial quality (not automotive) ethylene glycol or propylene glycol and water to provide freeze protection to a temperature 20ºF (11ºC) below the normal chiller operating temperature set point.

Glycol and/or water, with an inhibitor, should be used to protect the materials (copper, steel, stainless steel, and bronze) in the system from corrosion. If you intend to use straight water, we strongly advise a minimum leaving water temperature of 50ºF (10ºC) or contact the service department.

The following glycol products are available:

Part Number

Description

 

 

A0541358

Ethylene glycol, 5 gallons (18.9 liters)

 

 

A0539637

Ethylene glycol, 55 gallons (208.2 liters)

 

 

A0542990

Propylene glycol, 5 gallons (18.9 liters)

 

 

A0542991

Propylene glycol, 55 gallons (208.2 liters)

 

 

Caution! Do not connect make-up water directly to the chilled water reservoir unless you have an approved automatic water make-up system installed.

Note: The reservoir is not designed to withstand water pressure. The fill opening and vent line must be vented to the atmosphere for proper operation. The optional automatic make-up system is described in section 3-10 on page 27.

Caution! Do not pressurize tank. Fill and vent lines must be open to atmosphere. Supply and return connections must be trapped and vented to allow vertical risers to drain into tank. Do not overfill system. Allow enough free space in tank for vertical piping to drain.

If your application has chilled water or process piping above the reservoir fill and vent level, trap and vent the supply and return lines to allow vertical piping to drain into tank.

Note: In applications where the process or process piping is above the reservoir, take steps to prevent over pressurization of the reservoir. This condition can occur on system shutdown when the water in the system drains into the reservoir. To prevent this, a vacuum breaker should be installed at the high point of the “To Process” and “From Process” lines.

2-40 HP Portable Chillers

Chapter 3: Installation

25 of 70

Image 25
Contents Hp Portable Chillers Shipping Information Table of Contents Operation HP Portable Chillers How to Use This Manual SafetySafety Symbols Used in this Manual Responsibility Wear Safety Glasses and Work GlovesModels Covered in This Manual Functional DescriptionChilled Water Circuit General DescriptionRefrigeration Circuit Mechanical Features Standard FeaturesOther Mechanical Features Refrigeration Features Electrical FeaturesController Features Other FeaturesHigh/Low Thermostat Control Safety Devices and InterlocksCrankcase Heater High Pressure CutoutPressure Switch Fan Cycling SwitchFlow Switch Low Pressure CutoutOptional Features Mounting Features Optional Pump Amperages Voltage Construction Full Load Amps Uncrating InstallationElectrical Connections Bypass Valve Considerations Process Water ConnectionsGalvanic Corrosion Considerations Water Treatment ConsiderationsWater-Cooled Chiller Condensers Condenser ConsiderationsAir-Cooled Chiller Condensers Remote Air-Cooled Chiller Condensers Page Equivalent Length in Feet for Valves and Fittings Refrigerant Charge Determination Chiller Condenser Charge Field Installed Piping ChargeChecking Motor Direction Three-Phase CompressorsWater Pumps Condenser FanPart Number Description Water ReservoirEthylene Glycol and Propylene Glycol Curves Automatic Water Make-Up Option Initial Start-Up E5CK Controller Indicator Name Description Panel Buttons, Indicator Lights, and SwitchesOperation Microprocessor ControllersSterlco 2000 Controller Indicator Name Description Indicator Name DescriptionE5CK Graphic Panel See Figure Indicator Name DescriptionIndicator Name Description Eurotherm 3216 Controller Typical Graphic Panels With E5CK ControllerAuto-Tuning Setting the Process Water TemperaturesStart-up Optional CommunicationsProgramming the Electronic High/Low Thermostat Thermostat Buttons Indicator Name DescriptionSelect Fahrenheit or Celsius Stage 2 High Temperature ProtectionStage 1 Freeze Protection Filter Cleaning MaintenanceLubrication Maintaining the Evaporator Maintaining the CondenserEvaporator Process Piping Y-Strainer Air- and Remote Air-Cooled ChillersPreventative Maintenance Service HP Portable Chillers Troubleshooting TroubleshootingHP Portable Chillers Troubleshooting Appendix Warranty ReturnsReturned Material Policy Credit ReturnsTechnical Assistance Service DepartmentParts Department Sales DepartmentHp and 3 1/2 hp Air-Cooled Portable Chillers Drawings and SpecificationsHp and 7.5 hp Air-Cooled Portable Chillers Hp and 15 hp Air-Cooled Portable Chillers 20 hp, 25 hp, and 30 hp Air-Cooled Portable Chillers Nominal Condenser water Nominal cooling Water Com Hp and 3.5 hp Water-Cooled Portable ChillersIn. NPT Height Width Depth Lbs 28.3 22.0 41.7 28.3 22.0 41.7Hp and 7.5 hp Water-Cooled Portable Chillers Hp and 15 hp Water-Cooled Portable Chillers 20 hp, 25 hp, and 30 hp Water-Cooled Portable Chillers 39.5 39.1 98.4 Hp Water-Cooled Portable Chillers81.9 63.1 85.0 66.2 Hp and 7.5 hp Remote Air-Cooled Portable Chillers Nominal cooling Com Hp and 15 hp Remote Air-Cooled Portable ChillersIn. dia. ODS Pump Pumps Discharge Liquid Rated Running 15.0 40.9 34.0 74.7Nominal cooling Com Refrigeration Hp through 40 hp Remote Air-Cooled Portable ChillersPres Nom Connections To/from No tank Tank, to/from Height Width Depth Lbs‘A’in ‘B’in ‘C’in ‘D’in ODSin Remote Condenser Assembly ModelsHertz Pump Curves Pump Curves, Flow, and Pressure ConsiderationsDWG. No. S0554823 Calculating Chiller Nominal Flow and Pressure to Process Evaporator Water Pressure Drop TablesRecirc. power Flow Rate Pressure Gpm Lpm Psi KPa Recirculation Pump SpecificationsEvaporator Flow and Pressure Considerations Remote Air-Cooled Chiller Configurations Typical Ductwork for Air-Cooled Chillers Central and Gravity Return Piping with Standpipe Diagram Piping DiagramsTypical Piping Schematic, 2 and 3 1/2 hp Models HP Portable Chillers Appendix HP Portable Chillers Appendix Typical Piping Schematic, 5 hp through 40 hp, No-Pump Models HP Portable Chillers Appendix Typical Electrical Subpanel Electrical Schematics

A0554831 specifications

The Sterling A0554831 is a versatile and powerful tool designed for a range of applications, particularly in the industrial and construction sectors. Known for its robust construction and reliability, it has gained popularity among professionals and DIY enthusiasts alike.

One of the main features of the Sterling A0554831 is its durable build quality, which is designed to withstand harsh working conditions. The device typically features a high-strength casing that protects it from dust, moisture, and impact, ensuring longevity even in the most demanding environments. Its ergonomic design allows for comfortable handling, minimizing user fatigue during extended use.

In terms of performance, the Sterling A0554831 is equipped with advanced technologies that enhance its efficiency and functionality. The device is powered by a high-torque motor, delivering impressive power that enables it to tackle heavy-duty tasks with ease. The precision-engineered components ensure consistent performance, making it ideal for tasks that require accuracy and reliability.

Another significant characteristic of the Sterling A0554831 is its versatility. It typically comes with multiple settings and modes, allowing users to adjust the tool according to the specific requirements of their project. Whether drilling, cutting, or fastening, the tool can accommodate various tasks, making it a valuable addition to any toolkit.

Safety features are also a priority with the Sterling A0554831. Many models are equipped with overload protection and safety switches that prevent accidental activation, safeguarding the user during operation. Additionally, some variants may include LED indicators that provide real-time information about battery life or operational status, enhancing overall user experience.

In conclusion, the Sterling A0554831 stands out in the market for its combination of durability, performance, and versatility. With advanced technologies that cater to a wide range of applications and a design focused on user comfort and safety, this tool is an excellent choice for professionals looking for dependable and effective solutions in their work. Whether you are a seasoned professional or a casual DIYer, the Sterling A0554831 is well-equipped to handle your needs with ease and efficiency.