Sterling A0554831 manual Graphic Panel, See Figure Indicator Name Description

Page 32

Graphic Panel

(See Figure 8)

Indicator

 

Name

 

Description

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Compressor On

 

The Compressor On light turns on whenever the

 

 

 

 

 

 

 

 

 

 

 

 

 

Light

 

compressor is operating.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Low Temperature

The Low Temperature light comes on if the process

 

 

 

 

 

 

Light

water/glycol temperature drops below the High/Low

 

 

 

 

 

 

 

thermostat set point. The Low thermostat stage one

 

 

 

 

 

 

 

switch opens the control circuit shutting down the

 

 

 

 

 

 

 

compressor, but the process water/glycol pump(s)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

continue to operate. This action prevents possible

 

 

 

 

 

 

 

chiller evaporator freeze-up.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Hot Gas Bypass

 

The Hot Gas By-Pass light turns on when the hot

 

 

 

 

 

 

Light

 

gas bypass valve is in operation. The OUT1 LED on

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

the controller also lights when the hot gas bypass

 

 

 

 

 

 

 

 

valve is in operation.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

High Temperature

 

The High Temperature light comes on if the process

 

 

 

 

 

 

Light

 

water/glycol temperature rises above the High/Low

 

 

 

 

 

 

 

 

thermostat stage two set point. The High thermostat

 

 

 

 

 

 

 

 

stage two switch opens the control circuit shutting

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

down the process water/glycol pump(s), and the

 

 

 

 

 

 

 

 

chiller shuts off. This action prevents possible

 

 

 

 

 

 

 

 

system failure from overheating of the process

 

 

 

 

 

 

 

 

water/glycol.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Pump On Light

The Pump On light, installed on chillers with a

 

 

 

 

 

 

 

 

 

 

 

 

 

 

pump, lights whenever the pump(s) operates.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

High Discharge

 

The High Discharge Temperature light comes on if

 

 

 

 

 

 

Temperature Light

 

the compressor discharge line temperature switch

 

 

 

 

 

 

 

 

opens. This switch prevents possible compressor

 

 

 

 

 

 

 

 

failure due to over loading, the compressor stops,

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

but the pump(s) continue to run. This occurs when

 

 

 

 

 

 

 

 

the discharge line temperature rises above 260ºF

 

 

 

 

 

 

 

 

(127ºC). Call a qualified refrigeration service

 

 

 

 

 

 

 

 

technician or contact the Service Department.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Pump Overload

 

The Pump Overload light, installed on chillers with

 

 

 

 

 

 

Light

 

a pump(s), lights whenever a pump motor(s) has

 

 

 

 

 

 

 

 

shut down from a motor overload condition.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

High Refrigerant

 

The High Refrigerant Pressure light comes on if the

 

 

 

 

 

 

Pressure Light

 

compressor discharge pressure exceeds the limit of

 

 

 

 

 

 

 

 

the high pressure cutout switch. The compressor

 

 

 

 

 

 

 

 

stops but the pump(s) continue to run until you

 

 

 

 

 

 

 

 

manually reset the high-pressure cutout switch. Call

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

a qualified refrigeration service technician or

 

 

 

 

 

 

 

 

contact the Service Department.

 

 

 

 

 

 

 

 

 

2-40 HP Portable Chillers

Chapter 4: Operation

32 of 70

Image 32
Contents Hp Portable Chillers Shipping Information Table of Contents Operation HP Portable Chillers Safety Symbols Used in this Manual SafetyHow to Use This Manual Wear Safety Glasses and Work Gloves ResponsibilityFunctional Description Models Covered in This ManualRefrigeration Circuit General DescriptionChilled Water Circuit Other Mechanical Features Standard FeaturesMechanical Features Electrical Features Refrigeration FeaturesController Features Other FeaturesSafety Devices and Interlocks High/Low Thermostat ControlCrankcase Heater High Pressure CutoutFan Cycling Switch Pressure SwitchFlow Switch Low Pressure CutoutOptional Features Mounting Features Optional Pump Amperages Voltage Construction Full Load Amps Electrical Connections InstallationUncrating Process Water Connections Bypass Valve ConsiderationsGalvanic Corrosion Considerations Water Treatment ConsiderationsAir-Cooled Chiller Condensers Condenser ConsiderationsWater-Cooled Chiller Condensers Remote Air-Cooled Chiller Condensers Page Equivalent Length in Feet for Valves and Fittings Chiller Condenser Charge Field Installed Piping Charge Refrigerant Charge DeterminationThree-Phase Compressors Checking Motor DirectionWater Pumps Condenser FanWater Reservoir Part Number DescriptionEthylene Glycol and Propylene Glycol Curves Automatic Water Make-Up Option Initial Start-Up Panel Buttons, Indicator Lights, and Switches E5CK Controller Indicator Name DescriptionOperation Microprocessor ControllersIndicator Name Description Sterlco 2000 Controller Indicator Name DescriptionE5CK See Figure Indicator Name Description Graphic PanelIndicator Name Description Typical Graphic Panels With E5CK Controller Eurotherm 3216 ControllerSetting the Process Water Temperatures Auto-TuningStart-up Optional CommunicationsThermostat Buttons Indicator Name Description Programming the Electronic High/Low ThermostatStage 1 Freeze Protection Stage 2 High Temperature ProtectionSelect Fahrenheit or Celsius Lubrication MaintenanceFilter Cleaning Maintaining the Condenser Maintaining the EvaporatorEvaporator Process Piping Y-Strainer Air- and Remote Air-Cooled ChillersPreventative Maintenance Service Troubleshooting HP Portable Chillers TroubleshootingHP Portable Chillers Troubleshooting Warranty Returns AppendixReturned Material Policy Credit ReturnsService Department Technical AssistanceParts Department Sales DepartmentDrawings and Specifications Hp and 3 1/2 hp Air-Cooled Portable ChillersHp and 7.5 hp Air-Cooled Portable Chillers Hp and 15 hp Air-Cooled Portable Chillers 20 hp, 25 hp, and 30 hp Air-Cooled Portable Chillers Hp and 3.5 hp Water-Cooled Portable Chillers Nominal Condenser water Nominal cooling Water ComIn. NPT Height Width Depth Lbs 28.3 22.0 41.7 28.3 22.0 41.7Hp and 7.5 hp Water-Cooled Portable Chillers Hp and 15 hp Water-Cooled Portable Chillers 20 hp, 25 hp, and 30 hp Water-Cooled Portable Chillers 81.9 63.1 85.0 66.2 Hp Water-Cooled Portable Chillers39.5 39.1 98.4 Hp and 7.5 hp Remote Air-Cooled Portable Chillers Hp and 15 hp Remote Air-Cooled Portable Chillers Nominal cooling ComIn. dia. ODS Pump Pumps Discharge Liquid Rated Running 15.0 40.9 34.0 74.7Hp through 40 hp Remote Air-Cooled Portable Chillers Nominal cooling Com RefrigerationPres Nom Connections To/from No tank Tank, to/from Height Width Depth LbsRemote Condenser Assembly Models ‘A’in ‘B’in ‘C’in ‘D’in ODSinPump Curves, Flow, and Pressure Considerations Hertz Pump CurvesDWG. No. S0554823 Evaporator Water Pressure Drop Tables Calculating Chiller Nominal Flow and Pressure to ProcessEvaporator Flow and Pressure Considerations Recirculation Pump SpecificationsRecirc. power Flow Rate Pressure Gpm Lpm Psi KPa Remote Air-Cooled Chiller Configurations Typical Ductwork for Air-Cooled Chillers Piping Diagrams Central and Gravity Return Piping with Standpipe DiagramTypical Piping Schematic, 2 and 3 1/2 hp Models HP Portable Chillers Appendix HP Portable Chillers Appendix Typical Piping Schematic, 5 hp through 40 hp, No-Pump Models HP Portable Chillers Appendix Electrical Schematics Typical Electrical Subpanel

A0554831 specifications

The Sterling A0554831 is a versatile and powerful tool designed for a range of applications, particularly in the industrial and construction sectors. Known for its robust construction and reliability, it has gained popularity among professionals and DIY enthusiasts alike.

One of the main features of the Sterling A0554831 is its durable build quality, which is designed to withstand harsh working conditions. The device typically features a high-strength casing that protects it from dust, moisture, and impact, ensuring longevity even in the most demanding environments. Its ergonomic design allows for comfortable handling, minimizing user fatigue during extended use.

In terms of performance, the Sterling A0554831 is equipped with advanced technologies that enhance its efficiency and functionality. The device is powered by a high-torque motor, delivering impressive power that enables it to tackle heavy-duty tasks with ease. The precision-engineered components ensure consistent performance, making it ideal for tasks that require accuracy and reliability.

Another significant characteristic of the Sterling A0554831 is its versatility. It typically comes with multiple settings and modes, allowing users to adjust the tool according to the specific requirements of their project. Whether drilling, cutting, or fastening, the tool can accommodate various tasks, making it a valuable addition to any toolkit.

Safety features are also a priority with the Sterling A0554831. Many models are equipped with overload protection and safety switches that prevent accidental activation, safeguarding the user during operation. Additionally, some variants may include LED indicators that provide real-time information about battery life or operational status, enhancing overall user experience.

In conclusion, the Sterling A0554831 stands out in the market for its combination of durability, performance, and versatility. With advanced technologies that cater to a wide range of applications and a design focused on user comfort and safety, this tool is an excellent choice for professionals looking for dependable and effective solutions in their work. Whether you are a seasoned professional or a casual DIYer, the Sterling A0554831 is well-equipped to handle your needs with ease and efficiency.