Trane 750 CFM, 1500 CFM manual General Information

Page 5

General Information

Unit Nameplate

The unit nameplate is located in the left hand end pocket, behind the con- trol box. It includes the unit model number, serial number, electrical char- acteristics, and other pertinent unit da- ta.

Factory Shipment

Before shipment, each unit is leak test- ed, and run tested for proper control operation.

Access

A three panel front access of the unit ventilator allows for speedy set-up during field commissioning. This de- sign allows for the end pocket of the unit ventilator to be open while the fan (airside) section stays closed.

End Pockets

Access for piping and controls is made through the unit ventilator’s end pock- ets.

Coil Connections

The coil headers and drain connec- tions are made within the unit chassis to allow a tight seal and help prevent air leakage around the coil. The con- nection sizes vary dependent upon type of coil combination specified.

Coil Type

Size (in.)

Hydronic Cooling (Main) Coil or

3/4" Nominal

Heating/Cooling Changeover Coil

7/8" I.D.

Heating (Auxiliary) Coil

1/2" Nominal

5/8" I.D.

 

Steam Heating Coil

1" FNPT

Direct Expansion Coil

3/8" O.D. Liquid

7/8" O.D. Suction

 

Unit Drain Pan

The drain pan is dual-sloped for effec- tive condensate removal. It is made from a non-corrosive material to help eliminate issues associated to leaking or standing water. It may be easily re- moved for cleaning. The drain pan connection size for all Trane VUVE models is 7/8" O.D.

Motor

Motors for the VUVE model do not in- clude an external fan bearing on the end of the fan shaft. This helps avoid issues related to fan bearing mainte-

nance (oiling is not needed), and/or bearing replacement.

Filters

Filter sizing for the unit ventilator are an off-the-shelf design to reduce or help eliminate local stocking of the fil- ters.

Sliding Fan Deck

Convenient access to the fan motor and wheels for maintenance and ser- viceability may be made through Trane’s easy-slide fan deck design.

Outside/Return-Air Dampers

The outside-air/return-air damper is a one piece, linkage free design result- ing in a superior air-tight seal.

Field Installed Controls (Option)

The unit comes equipped with a fan speed switch, damper blade (only), and an optional low temperature de- tection.

End Device Control Package (Option)

Units containing the End Device con- trol design will incorporate a pre- wired, selected control components to a terminal strip for wiring a field pro- vided controller and temperature sen- sor.

Note: for controller operation malfunc- tion of any non-Trane, field installed controls, consult the literature or tech- nical support of the controls manufac- turer.

Tracer™ ZN520 Control Package

(Option)

The ZN520 electronic digital controller is a factory installed, tested and com- missioned LonTalk™ certified design. It may be used in a stand-alone control scheme, or as part of a building auto- mation system. The controller is pre- wired to Trane selected control com- ponents best suited for room comfort. For more information on the ZN520 unit controller operation and service issues, refer to CNT-SVX04A-EN (ZN520 control manual).

UV-SVN03D-EN

5

Image 5
Contents Later Design Sequence Installation Owner MaintenanceAmerican Standard All rights reserved Contents Jobsite Inspection Pre-installation ChecklistGeneral Information Isolation Valve Option OA/RA Actuator OptionImproper Unit Lift Dimensions/Weights ClearanceDimensions Falseback Unit Dynamic Air Barrier Unit End Covers Wall Boxes Crossover Piping Wall Box Installation InstallationInstallation in Masonry Walls Installation in Curtain WallsUnit Mounting General Installation ChecksLocation Considerations Mounting hole location End Panels Subbase optionInstallation Crossover Piping Piping InstallationSteam Piping Split System UnitsRefrigerant Piping Plumbing the Valve AB 3-way valveIsolation Valves Installation WiringManually Opening Valve Servicing/Removal of ValvesControl Power Soldering procedures are as followsSupply Power Heating Coils with Direct Expansion CoolingSplit System Start-Up DX SystemTable E1 VUV 075-150, Electrical Performance Electrical RequirementsVUVE125 Pre-Start-up Checklist Pre-Start ChecklistFilter Replacement MaintenancePeriodic Maintenance Fan board removal for fan/ motor access Preventive Maintenance Coil CleaningWarranty Information Standard Warranty Warranty InformationProblem Heating Cooling Cause Correction Room too warm Trouble Shooting ChecklistProblem Room too cool Heating Cooling Cause Correction 120V/1 PH 3-Speed Unit Wiring120V/1 PH 3-Speed, DX/Hot Water End Device Package End Device Package 120V/1 PH 3-Speed, 4-Pipe Hot Water/Chilled Water Tracer ZN520 UV-SVN03D-EN Trane

750 CFM, 1500 CFM specifications

Trane has long been a leader in the heating, ventilation, and air conditioning (HVAC) industry, and among its extensive product range, the Trane 1500 CFM and 750 CFM air handling units stand out due to their innovative design and performance capabilities. These units are engineered to provide exceptional airflow and efficiency, catering to a variety of commercial and industrial environments.

One of the main features of the Trane 1500 CFM and 750 CFM units is their ability to maintain optimal indoor air quality. Both units feature high-efficiency air filters that effectively capture dust, allergens, and other airborne particles, ensuring that the air quality remains high. This is particularly important in commercial spaces, where the health and comfort of occupants is a top priority.

In terms of energy efficiency, the Trane units are equipped with advanced technologies that minimize energy consumption while maximizing cooling and heating performance. The units are designed to comply with the most stringent efficiency standards, making them an environmentally friendly choice. The use of variable speed fans allows for precise control over airflow, further enhancing energy savings by adjusting to the specific demands of the space.

Another notable characteristic of the Trane air handling units is their robust construction. Built with high-quality materials, they are designed to withstand harsh environmental conditions, ensuring durability and reliability over long periods of use. The units come with sound-attenuating features, making them suitable for noise-sensitive environments, while their compact design facilitates easy installation in limited spaces.

Trane also integrates smart technology into its air handling units, enabling connectivity with building management systems (BMS). This feature allows for real-time monitoring and remote control of unit operations, providing facility managers with valuable insights into performance and energy usage. Such connectivity not only improves operational efficiency but also simplifies maintenance tasks by providing timely alerts and diagnostics.

In summary, the Trane 1500 CFM and 750 CFM air handling units are designed with key features that enhance air quality, energy efficiency, and user convenience. Their innovative technologies and durable construction make them a reliable choice for various commercial applications, ensuring a comfortable and healthy indoor environment for all occupants. With Trane's commitment to quality and performance, these units represent the forefront of HVAC technology.