GE JVB93 Installation Instructions, Tools You Will Need, Take Measurements, Specifications

Page 5

INSTALLATION INSTRUCTIONS

Tools You Will Need

Flat blade and Phillips

 

 

 

Pencil

 

screwdrivers

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Duct tapeSaw (saber or keyhole)

(OR other depending upon material)

Electric Drill

Metal Snips

 

(in some applications)

1/4Through 7/16

 

Pivoting Hex Socket

Pliers

Tape measure

 

 

 

Wire stripper

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

FlashlightCaulking

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Level

 

 

1/4Through 7/16

 

 

 

 

 

 

 

 

 

 

Nut Driver

 

 

 

 

 

 

 

 

Before Starting Installation,

Check the Following

Requirements

This downdraft blower system is designed to be used to exhaust smoke and odors when cooking with all GE electric and sealed burner gas cooktops (not approved for standard burner gas cooktops). It can be mounted in either an island or peninsula location.

Requirements for an approved installation

26″ minimum cabinet depth

26″ minimum from the back of the downdraft to the front of the countertop

2312″ minimum FLAT countertop surface

NOTE: JGP932S, JP350SC, JP930SC and JP938SC require 2358″ flat surface area.

Plan the placement of the electrical outlet box carefully. It should NOT be installed on the back wall of the cabinet because it may interfere with the downdraft. It should be installed on a side wall or adjacent cabinet. Make sure it is within reach of the unit’s 2-ft. long power cord and conforms to all local codes.

Install a standard wiring box with a 3-pronged outlet.

Plan the location of the gas supply pipe (for gas cooktops) carefully to avoid interference with the downdraft installation.

Specifications

This unit can be easily installed following these basic steps:

Cut out the countertop opening.

Install the downdraft in the cabinet.

Connect the ductwork and electrical.

Install the cooktop.

VOLTS

AMPS

CFM

DUCT

120

4.0

500

314 X 10

Take Measurements

Refer to the cooktop installation instructions for dimensions of cooktop, countertop cut-out, and cabinet requirements.

The 30″ models will fit in most 30″ wide cabinets and the 36″ models will fit in most 36″ wide cabinets.

To install a cooktop with this downdraft, the cabinet depth must be 26″ minimum.

Flat counter area

26

Minimum 26

Cabinet depth required

A countertop with a raised lip may not allow enough flat countertop for a proper installation.

Before starting installation, review the following pages carefully.

Cutout dimension and illustrations are given for 30″ and 36″ cooktops.

(continued next page) 5

Image 5
Contents Care and Cleaning Safety Instructions Operating Instructions, TipsProblem Solver GE AppliancesRead and Save These Instructions Servicing Using Your Downdraft Vent SystemCooking Tips OFF Before Servicing the UnitQUESTIONS? USE this Problem Solver Care and CleaningProblem Possible Cause Do not use a steel wool pad it will scratch the surfaceRequirements for an approved installation Installation InstructionsSpecifications Tools You Will NeedCutout for 30″ COOKTOPS/DOWNDRAFT Units JVB93JGP960S 36″ COOKTOPS/DOWNDRAFT Units JVB96Steps to Determine Flexible Ducting’s Equivalent Length Plan the DuctworkPreparation Plan the WiringChanging Blower Discharge Optional Down DischargeInstall the Electrical Wiring Install the DowndraftInstall the Ductwork To adjust position of activating switch Install the CooktopAdjust the Switch Warranty

JVB93 specifications

The GE JVB93 is a sophisticated gas turbine designed for both industrial and utility applications, known for its exceptional efficiency and reliability. As part of GE's lineage of advanced gas turbines, the JVB93 incorporates cutting-edge technology to provide a competitive edge in terms of performance and environmental sustainability.

One of the primary features of the GE JVB93 is its high efficiency. The turbine boasts a thermal efficiency exceeding 45%, which translates to reduced fuel consumption and lower greenhouse gas emissions compared to traditional gas turbines. This efficiency is achieved through the utilization of advanced materials and innovative cooling techniques, enabling the turbine to operate at higher temperatures while maintaining structural integrity.

The JVB93 utilizes advanced aerodynamics in its compressor design, which optimizes airflow and improves overall performance. This state-of-the-art compressor is capable of handling variable operating conditions, ensuring reliable performance across a wide range of loads. The turbine also features a modular design, facilitating easier maintenance and quicker upgrades, ultimately reducing downtime and operational costs for users.

In terms of emissions control, the GE JVB93 is engineered with low NOx combustion technology. This means that the turbine produces significantly lower nitrogen oxides during operation, meeting stringent environmental regulations without compromising on performance. The combination of advanced burner technology and precise fuel management helps deliver clean and efficient power, making it an appealing option for companies focused on sustainability.

Another notable characteristic of the GE JVB93 is its versatility. The turbine can accommodate various fuel types, including natural gas, biogas, and liquid fuels, making it suitable for a range of applications from peaking power plants to continuous baseload operations. This adaptability allows facilities to optimize their fuel procurement strategies and enhance energy security.

Furthermore, the JVB93 is equipped with advanced digital technologies, allowing for real-time monitoring and predictive analytics. These capabilities enable operators to identify potential issues before they escalate, facilitating proactive maintenance strategies that enhance reliability and performance over time.

In summary, the GE JVB93 gas turbine stands out due to its high efficiency, low emissions, and advanced technology. Its modular design, versatile fuel capabilities, and digital integration make it an excellent choice for industries seeking to improve energy efficiency while adhering to environmental standards. This combination of features positions the JVB93 as a key player in the global push for cleaner, more sustainable energy solutions.