Toshiba SR-C8002 21/24, Emergency Release, Safety Standards/Agency Approvals Tentative

Page 26

11.Emergency Release

Execute following procedure only in the case of emergency (Drawer will not release and disc can not be removed although pressing Release Button).

(1)Turn the drive supplying power off.

(2)Insert solid bar (like paper clip) into Emergency Release hole and push as shown in Fig.19. Then Drawer will be released.

(3)After removed the disc, gently push Drawer to close.

15 mm

diameter 1.0 mm

 

Figurer 19 Emergency Release

12.Safety Standards/Agency Approvals (TENTATIVE)

(1) Safety

EN60950

 

UL 1950

 

CAN/CSA-22.2 No.950

(2) Laser

FDA 21CFR (U.S.A./DHHS)

 

EN60825-1 (Europe)

(3) EMC

CE

EN55022

: 1998 [Radio disturbance characteristics-IT

 

equipment Class B (including domestic

 

environment

EN55024 (EMS)

: 1998 [Information Technology equipment-

 

Immunity characteristices Limits and

 

methods of masurement]

IEC61000-4-2+A1

: 1995+1998 [CD:4 kV, ID: 4 kV, AD:8 kV]

IEC61000-4-3

: 1996 [3 V/m, 80-1000 MHz, 1 kHz 80 % AM ]

IEC61000-4-4

: 1995 [AC-line: 1 kV, I/F 0.5 kV

 

f: 5 kHz, Polarity: +/-]

IEC61000-4-5

: 1995 [AC-line: 2 kV/1 kV, Polarity: +/-]

IEC61000-4-6

: 1996 [3 V, 0.15-80 MHz, 80 % AM]

IEC61000-4-8

: 1993 [1 A/m, 50 Hz]

IEC61000-4-11

: 1994 [>95 % 0.5, 30% 25, >95 250]

KOREAN EMC No. 13237

TAIWAN EMI CNS 13438

21/24

SR-C8002 Rev.1.0

Image 26
Contents Toshiba Limitation of Liability SR-C8002 Rev.1.0 Contents SR-C8002 Rev.1.0 Features IntroductionSpecifications CD-DA, CD+EG, CD-MIDI, CD-ROM,CD-ROM XASR-C8002 Rev.1.0 SR-C8002 Rev.1.0 14.7 m/s2 1.5 G Horizontal M/s2 0.8 G Installation Conditions R63 R59 R46 Do not add Force External Dimensions Configuration CD-R / RW Drive Model SR-C8002 Block Diagram 11/24 Functions12/24 InterfaceShows the Signal Specifications 13/2414/24 Shows the Host Interface Timings15/24 Shows the Host Interface DMA multi word TimingsConnector pin assignments 16/24Support Command List Atapi Packet Command 17/2418/24 Power RequirementsOP Code Command Description 19/24 CD Audio Test condition Ordinary temperatureDevice Configuration Jumper Busy Indicator 20/24Emergency Release Safety Standards/Agency Approvals Tentative21/24 Electrostatic Discharge Accessories22/24 Packaging23/24 Document No.YEA R2597Page1Product/Options Model Related EU-Directive 89/336/EEC 24/24ED-Directive Related Standard Issude Level/Test condition Document No YEA-R2597 RevisionSuch as 95 ms access Time CD-RWG e I t e m Rev # 0 Rev # 1